{"title":"DTS Technology","description":"\u003cstyle\u003e .abatec-fotas-dts { --ab-blue:#0b369d; --ab-navy:#0b1d52; --ab-ink:#172235; --ab-muted:#59677a; --ab-line:#dce2ea; --ab-soft:#f4f7fb; --ab-warm:#fff7e8; --ab-orange:#ffb33c; color:var(--ab-ink); font-family:inherit; font-size:16px; line-height:1.6; margin:0 auto; max-width:1180px; overflow:hidden; } .abatec-fotas-dts .ab-skip { background:#fff; border:2px solid var(--ab-blue); color:var(--ab-blue); left:-9999px; padding:.55rem .8rem; position:absolute; z-index:10; } .abatec-fotas-dts .ab-skip:focus { left:1rem; top:1rem; } .abatec-fotas-dts .ab-hero { background:linear-gradient(120deg,var(--ab-blue) 0 52%,var(--ab-navy) 52% 100%); border-radius:12px; color:#fff; display:grid; grid-template-columns:1fr; margin:0 0 1.25rem; overflow:hidden; } .abatec-fotas-dts .ab-hero-copy { padding:clamp(1.4rem,5vw,3.4rem); } .abatec-fotas-dts .ab-eyebrow { align-items:center; display:flex; font-size:.86rem; font-weight:700; gap:.65rem; letter-spacing:.08em; margin:0 0 .75rem; text-transform:uppercase; } .abatec-fotas-dts .ab-eyebrow::before { background:var(--ab-orange); content:\"\"; height:3px; width:28px; } .abatec-fotas-dts .ab-topic-title,.abatec-fotas-dts h2,.abatec-fotas-dts h3 { color:var(--ab-ink); line-height:1.18; margin:0 0 .7rem; } .abatec-fotas-dts .ab-topic-title { color:#fff; font-size:clamp(2rem,5vw,3.4rem); max-width:16ch; } .abatec-fotas-dts h2 { font-size:clamp(1.65rem,3.7vw,2.35rem); } .abatec-fotas-dts h3 { font-size:1.14rem; } .abatec-fotas-dts p { margin:.3rem 0 1rem; } .abatec-fotas-dts .ab-lead { font-size:clamp(1.05rem,2vw,1.24rem); max-width:62ch; } .abatec-fotas-dts .ab-buttons { display:flex; flex-wrap:wrap; gap:.75rem; margin-top:1.25rem; } .abatec-fotas-dts .ab-button { align-items:center; border:2px solid transparent; border-radius:6px; display:inline-flex; font-weight:700; justify-content:center; min-height:44px; padding:.68rem 1rem; text-decoration:none; } .abatec-fotas-dts .ab-button-primary { background:var(--ab-orange); color:#102967; } .abatec-fotas-dts .ab-button-secondary { border-color:#fff; color:#fff; } .abatec-fotas-dts a { color:var(--ab-blue); text-decoration-thickness:1px; text-underline-offset:3px; } .abatec-fotas-dts a:hover { text-decoration-thickness:2px; } .abatec-fotas-dts a:focus-visible { outline:3px solid var(--ab-orange); outline-offset:3px; } .abatec-fotas-dts .ab-hero-media { background:#fff; min-height:280px; } .abatec-fotas-dts .ab-hero-media img { display:block; height:100%; object-fit:cover; width:100%; } .abatec-fotas-dts .ab-kern { border:1px solid var(--ab-line); display:grid; grid-template-columns:1fr; margin:0 0 2.8rem; } .abatec-fotas-dts .ab-kern div { padding:1rem 1.15rem; } .abatec-fotas-dts .ab-kern div + div { border-top:1px solid var(--ab-line); } .abatec-fotas-dts .ab-kern strong { color:var(--ab-blue); display:block; } .abatec-fotas-dts .ab-section { padding:clamp(2rem,5vw,4.2rem) clamp(1rem,3vw,2rem); } .abatec-fotas-dts .ab-section-soft { background:var(--ab-soft); border-radius:12px; } .abatec-fotas-dts .ab-intro { color:var(--ab-muted); font-size:1.06rem; max-width:75ch; } .abatec-fotas-dts .ab-grid { display:grid; gap:1rem; grid-template-columns:1fr; margin-top:1.25rem; } .abatec-fotas-dts .ab-card { background:#fff; border:1px solid var(--ab-line); border-radius:9px; padding:1.2rem; } .abatec-fotas-dts .ab-card p:last-child,.abatec-fotas-dts .ab-card ul:last-child { margin-bottom:0; } .abatec-fotas-dts .ab-card-label { color:var(--ab-blue); font-size:.78rem; font-weight:700; letter-spacing:.07em; margin-bottom:.35rem; text-transform:uppercase; } .abatec-fotas-dts .ab-callout { background:var(--ab-warm); border-left:5px solid var(--ab-orange); border-radius:5px; margin:1.2rem 0; padding:1rem 1.15rem; } .abatec-fotas-dts .ab-steps { counter-reset:step; display:grid; gap:1rem; grid-template-columns:1fr; list-style:none; margin:1.4rem 0 0; padding:0; } .abatec-fotas-dts .ab-steps li { background:#fff; border:1px solid var(--ab-line); border-radius:9px; padding:1.1rem; } .abatec-fotas-dts .ab-steps li::before { align-items:center; background:var(--ab-blue); border-radius:50%; color:#fff; content:counter(step); counter-increment:step; display:flex; font-weight:700; height:2rem; justify-content:center; margin-bottom:.7rem; width:2rem; } .abatec-fotas-dts ul { padding-left:1.2rem; } .abatec-fotas-dts li + li { margin-top:.4rem; } .abatec-fotas-dts .ab-figure { background:#fff; border:1px solid var(--ab-line); border-radius:10px; margin:1.5rem 0 0; overflow:hidden; } .abatec-fotas-dts .ab-figure img { display:block; height:auto; width:100%; } .abatec-fotas-dts .ab-figure figcaption { color:var(--ab-muted); font-size:.9rem; padding:.75rem 1rem; } .abatec-fotas-dts .ab-table-scroll { border:1px solid var(--ab-line); border-radius:9px; margin-top:1.2rem; overflow-x:auto; } .abatec-fotas-dts table { border-collapse:collapse; min-width:760px; width:100%; } .abatec-fotas-dts th,.abatec-fotas-dts td { border-bottom:1px solid var(--ab-line); padding:.85rem; text-align:left; vertical-align:top; } .abatec-fotas-dts th { background:var(--ab-navy); color:#fff; } .abatec-fotas-dts tr:last-child td { border-bottom:0; } .abatec-fotas-dts .ab-current td { background:#fff1d7; } .abatec-fotas-dts .ab-current td:first-child { border-left:5px solid var(--ab-orange); font-weight:700; } .abatec-fotas-dts .ab-product-note { background:#fff; border:1px solid var(--ab-line); border-radius:9px; padding:1.2rem; } .abatec-fotas-dts .ab-project { background:var(--ab-navy); border-radius:12px; color:#fff; } .abatec-fotas-dts .ab-project h2,.abatec-fotas-dts .ab-project h3 { color:#fff; } .abatec-fotas-dts .ab-project a:not(.ab-button) { color:#fff; } .abatec-fotas-dts .ab-faq details { border-top:1px solid var(--ab-line); padding:.9rem 0; } .abatec-fotas-dts .ab-faq details:last-child { border-bottom:1px solid var(--ab-line); } .abatec-fotas-dts .ab-faq summary { color:var(--ab-ink); cursor:pointer; font-weight:700; } .abatec-fotas-dts .ab-faq summary:focus-visible { outline:3px solid var(--ab-orange); outline-offset:4px; } .abatec-fotas-dts .ab-faq details p { color:var(--ab-muted); margin:.65rem 0 .2rem; max-width:78ch; } .abatec-fotas-dts .ab-note { color:var(--ab-muted); font-size:.92rem; } @media (min-width:700px) { .abatec-fotas-dts .ab-grid-2 { grid-template-columns:repeat(2,minmax(0,1fr)); } .abatec-fotas-dts .ab-grid-3 { grid-template-columns:repeat(3,minmax(0,1fr)); } .abatec-fotas-dts .ab-steps { grid-template-columns:repeat(2,minmax(0,1fr)); } .abatec-fotas-dts .ab-kern { grid-template-columns:repeat(3,1fr); } .abatec-fotas-dts .ab-kern div + div { border-left:1px solid var(--ab-line); border-top:0; } } @media (min-width:900px) { .abatec-fotas-dts .ab-hero { grid-template-columns:1.03fr .97fr; } .abatec-fotas-dts .ab-steps { grid-template-columns:repeat(4,minmax(0,1fr)); } } @media (prefers-reduced-motion:reduce) { .abatec-fotas-dts a { scroll-behavior:auto; } } .ab-category-details .abatec-fotas-dts img{max-width:100%;max-height:none}.ab-category-details .abatec-fotas-dts .ab-hero-media img{height:100%;object-fit:contain}.fotas-details{scroll-margin-top:160px}#ab-produkte{scroll-margin-top:160px} \u003c\/style\u003e\u003carticle id=\"fotas-details\" class=\"abatec-fotas-dts fotas-details\" aria-labelledby=\"dts-titel\"\u003e\n  \u003ca class=\"ab-skip\" href=\"#ab-produkte\"\u003eDirekt zu den Produkten\u003c\/a\u003e\n  \u003cheader class=\"ab-hero\"\u003e\n    \u003cdiv class=\"ab-hero-copy\"\u003e\n      \u003cp class=\"ab-eyebrow\"\u003eFOTAS | Verteilte Temperaturmessung\u003c\/p\u003e\n      \u003ch1 class=\"ab-topic-title\" id=\"dts-titel\"\u003eDistributed Temperature Sensing (DTS)\u003c\/h1\u003e\n      \u003cp class=\"ab-lead\"\u003eKonkrete Temperaturen entlang einer Sensorfaser kontinuierlich messen und thermische Ereignisse räumlich zuordnen – auch dort, wo punktuelle Fühler große Lücken lassen würden.\u003c\/p\u003e\n      \u003cdiv class=\"ab-buttons\"\u003e\n        \u003ca class=\"ab-button ab-button-primary\" href=\"mailto:shop@abatec.de?subject=FOTAS%20DTS%20Projektanfrage\" target=\"_blank\" rel=\"noopener\" aria-describedby=\"a11y-new-window-message\"\u003eFOTAS-Projekt mit Abatec besprechen\u003c\/a\u003e\n        \u003ca class=\"ab-button ab-button-secondary\" href=\"#ab-produkte\"\u003eProdukte dieser Kategorie\u003c\/a\u003e\n      \u003c\/div\u003e\n    \u003c\/div\u003e\n    \u003cdiv class=\"ab-hero-media\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1111\/8768\/9862\/files\/fotas-dts-1.webp?v=1791444576\" alt=\"DTS-Prinzip mit Temperaturprofil, Sensorfaser und FOTAS APEX Auswerteeinheit\" width=\"1200\" height=\"633\" fetchpriority=\"high\" loading=\"lazy\" decoding=\"async\"\u003e\u003c\/div\u003e\n  \u003c\/header\u003e\n  \u003cdiv class=\"ab-kern\" aria-label=\"Technologie auf einen Blick\"\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eDirekt gemessen\u003c\/strong\u003eOrtsaufgelöste Temperaturwerte entlang der Sensorfaser\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003eTypische Frage\u003c\/strong\u003eWie warm ist es an dieser Position?\u003c\/div\u003e\n\u003cdiv\u003e\n\u003cstrong\u003ePassend für\u003c\/strong\u003eTunnel, Kabeltrassen, Energieanlagen, Pipelines und industrielle Prozesse\u003c\/div\u003e\n\u003c\/div\u003e\n\n  \u003c\/article\u003e\u003c!--abatec-details--\u003e\u003carticle class=\"abatec-fotas-dts fotas-details\" aria-labelledby=\"dts-titel\"\u003e\n  \u003csection class=\"ab-section\" aria-labelledby=\"was-ist-dts\"\u003e\n    \u003cp class=\"ab-card-label\"\u003eGrundlagen\u003c\/p\u003e\n\u003ch2 id=\"was-ist-dts\"\u003eWas ist DTS?\u003c\/h2\u003e\n    \u003cdiv class=\"ab-grid ab-grid-2\"\u003e\n\u003cdiv\u003e\n\u003cp\u003eDTS steht für Distributed Temperature Sensing. Eine geeignete Glasfaser dient über ihre Länge als kontinuierlicher Temperatursensor. Das System erzeugt kein einzelnes Messsignal an wenigen Punkten, sondern ein Temperaturprofil entlang der Route. So werden thermische Veränderungen nicht nur sichtbar, sondern auch einer Position zugeordnet.\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"\/collections\/fotas-sensortechnik\"\u003eDAS, DTS und DTGS im Überblick\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003caside class=\"ab-callout\"\u003e\u003cstrong\u003eEinfach unterschieden\u003c\/strong\u003e\u003cp\u003eDTS beantwortet vor allem: „Wie warm ist es an dieser Position?“ Grenzwerte, Anstiegsraten und Alarmzonen können je nach System und Anwendung ausgewertet werden. Ob eine Temperaturabweichung auf Brand, Überlastung, Leckage oder einen Prozesszustand zurückgeht, muss im Anlagenkontext bewertet werden.\u003c\/p\u003e\u003c\/aside\u003e\n\u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"ab-section ab-section-soft\" aria-labelledby=\"funktion-dts\"\u003e\n    \u003cp class=\"ab-card-label\"\u003eMessprinzip\u003c\/p\u003e\n\u003ch2 id=\"funktion-dts\"\u003eSo funktioniert die Technologie\u003c\/h2\u003e\n    \u003cp class=\"ab-intro\"\u003eVom optischen Signal bis zur nutzbaren Information in vier Schritten. Details wie Pulsfolge, Auflösung, Mittelung und Auswertealgorithmus hängen von System und Projekt ab.\u003c\/p\u003e\n    \u003col class=\"ab-steps\"\u003e\n\u003cli\u003e\n\u003ch3\u003eLicht einspeisen\u003c\/h3\u003e\n\u003cp\u003eKurze Laserimpulse laufen durch die faseroptische Sensorstrecke.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ch3\u003eRaman-Signal erfassen\u003c\/h3\u003e\n\u003cp\u003eStokes- und temperaturabhängige Anti-Stokes-Anteile werden zurückgestreut.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ch3\u003eTemperatur berechnen\u003c\/h3\u003e\n\u003cp\u003eDas Verhältnis der Signalanteile dient zur Berechnung der Temperatur.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003ch3\u003eOrt zuordnen\u003c\/h3\u003e\n\u003cp\u003eDie Signallaufzeit verknüpft den Temperaturwert mit seiner Position entlang der Faser.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"ab-section\" aria-labelledby=\"erkennt-dts\"\u003e\n    \u003cp class=\"ab-card-label\"\u003eSaubere Trennung\u003c\/p\u003e\n\u003ch2 id=\"erkennt-dts\"\u003eWas erkennt das System?\u003c\/h2\u003e\n    \u003cp class=\"ab-intro\"\u003eMessgröße, Analyseergebnis und Anwendung sind nicht dasselbe. Welche Ereignisse belastbar erkannt oder klassifiziert werden, muss für Faser, Einbauort und Umgebung validiert werden.\u003c\/p\u003e\n    \u003cdiv class=\"ab-grid ab-grid-3\"\u003e\n\u003carticle class=\"ab-card\"\u003e\u003ch3\u003eDirekt gemessene Größe\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eTemperatur entlang der Sensorfaser\u003c\/li\u003e\n\u003cli\u003eOrtsbezogenes Temperaturprofil\u003c\/li\u003e\n\u003cli\u003eZeitlicher Verlauf der Messwerte\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/article\u003e\u003carticle class=\"ab-card\"\u003e\u003ch3\u003eMögliche Analyse\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLokaler Temperaturanstieg\u003c\/li\u003e\n\u003cli\u003eÜber- oder Unterschreitung definierter Werte\u003c\/li\u003e\n\u003cli\u003eAnstiegsrate oder Hotspot – sofern konfiguriert\u003c\/li\u003e\n\u003cli\u003eThermische Abweichung vom Betriebszustand\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/article\u003e\u003carticle class=\"ab-card\"\u003e\u003ch3\u003eMögliche Anwendung\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eLineare Wärme- und Branddetektion\u003c\/li\u003e\n\u003cli\u003eEnergie- und Stromkabelmonitoring\u003c\/li\u003e\n\u003cli\u003eTunnel, Kabelgänge und technische Räume\u003c\/li\u003e\n\u003cli\u003eProzess-, Pipeline- und Anlagenüberwachung\u003c\/li\u003e\n\u003c\/ul\u003e\u003c\/article\u003e\n\u003c\/div\u003e\n    \u003cfigure class=\"ab-figure\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1111\/8768\/9862\/files\/fotas-dts-2.webp?v=1791444576\" alt=\"DTS-Anwendungsübersicht mit Energieanlage, Pipeline, Tunnel, Tanklager und Temperaturprofil\" width=\"900\" height=\"600\" loading=\"lazy\" decoding=\"async\"\u003e\u003cfigcaption\u003eHerstellerdarstellung zur fachlichen Einordnung; konkrete Erkennungs- und Alarmfunktionen sind modell- und projektabhängig.\u003c\/figcaption\u003e\u003c\/figure\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"ab-section ab-section-soft\" aria-labelledby=\"einsatz-dts\"\u003e\n    \u003cp class=\"ab-card-label\"\u003eAnwendungen\u003c\/p\u003e\n\u003ch2 id=\"einsatz-dts\"\u003eTypische Einsatzbereiche\u003c\/h2\u003e\n    \u003cdiv class=\"ab-grid ab-grid-3\"\u003e\n\u003carticle class=\"ab-card\"\u003e\u003ch3\u003eTunnel \u0026amp; Kabelgänge\u003c\/h3\u003e\n\u003cp\u003eDurchgehende Temperaturabdeckung entlang ausgedehnter Verkehrs- und Versorgungswege.\u003c\/p\u003e\u003c\/article\u003e\u003carticle class=\"ab-card\"\u003e\u003ch3\u003eEnergie- und Stromkabel\u003c\/h3\u003e\n\u003cp\u003eHotspots und ungewöhnliche Erwärmung entlang von Kabelrouten lokalisieren.\u003c\/p\u003e\u003c\/article\u003e\u003carticle class=\"ab-card\"\u003e\u003ch3\u003eIndustrieanlagen\u003c\/h3\u003e\n\u003cp\u003eTemperaturverläufe an Förderern, Öfen, Reaktoren, Lagern oder Produktionsanlagen überwachen.\u003c\/p\u003e\u003c\/article\u003e\u003carticle class=\"ab-card\"\u003e\u003ch3\u003ePipelines \u0026amp; Prozesse\u003c\/h3\u003e\n\u003cp\u003eTemperaturanomalien im Zusammenhang mit Leckagen oder Prozessänderungen als Hinweis auswerten.\u003c\/p\u003e\u003c\/article\u003e\u003carticle class=\"ab-card\"\u003e\u003ch3\u003eRechenzentren \u0026amp; Technikräume\u003c\/h3\u003e\n\u003cp\u003eThermische Entwicklungen entlang definierter Sensorwege überwachen; Brandschutzkonzept und Zulassungen separat prüfen.\u003c\/p\u003e\u003c\/article\u003e\u003carticle class=\"ab-card\"\u003e\u003ch3\u003eLineare Wärmedetektion\u003c\/h3\u003e\n\u003cp\u003eTemperatur-, Anstiegsraten- oder Zonenalarme je nach Plattform und Projektanforderung konfigurieren.\u003c\/p\u003e\u003c\/article\u003e\n\u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"ab-section\" aria-labelledby=\"vergleich-dts\"\u003e\n    \u003cp class=\"ab-card-label\"\u003eAuswahlhilfe\u003c\/p\u003e\n\u003ch2 id=\"vergleich-dts\"\u003eFOTAS DAS, DTS oder DTGS – was ist der Unterschied?\u003c\/h2\u003e\n    \u003cdiv class=\"ab-table-scroll\" tabindex=\"0\" role=\"region\" aria-label=\"Vergleich von DAS, DTS und DTGS\"\u003e\n      \u003ctable\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eTechnologie\u003c\/th\u003e\n\u003cth\u003eErfasst \/ analysiert\u003c\/th\u003e\n\u003cth\u003eTypische Fragestellung\u003c\/th\u003e\n\u003cth\u003eGeeignete Anwendungen\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr class=\"\"\u003e\n\u003ctd\u003e\u003ca href=\"\/collections\/das-technology\"\u003eDAS\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eVibrationen und akustisch geprägte mechanische Einwirkungen\u003c\/td\u003e\n\u003ctd\u003eWas ist wo passiert?\u003c\/td\u003e\n\u003ctd\u003ePerimeter, Zaun, Grabung, Trassen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"ab-current\"\u003e\n\u003ctd\u003e\u003cstrong aria-current=\"page\"\u003eDTS – diese Seite\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eKonkrete Temperaturwerte und Temperaturprofile\u003c\/td\u003e\n\u003ctd\u003eWie warm ist es an dieser Position?\u003c\/td\u003e\n\u003ctd\u003eWärme-, Brand-, Kabel- und Anlagenmonitoring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr class=\"\"\u003e\n\u003ctd\u003e\u003ca href=\"\/collections\/fotas-dtgs-technology\"\u003eDTGS\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003eThermische Trends, Raten, Gradienten und Abweichungen\u003c\/td\u003e\n\u003ctd\u003eWie verändert sich das thermische Verhalten über Zeit und Strecke?\u003c\/td\u003e\n\u003ctd\u003eThermische Zustands- und Trendüberwachung\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n    \u003c\/div\u003e\n    \u003cp class=\"ab-note\"\u003eDie Tabelle dient der Orientierung. Eine Kombination aus akustischer und thermischer Sensorik kann sinnvoll sein; sie ersetzt keine Projektprüfung.\u003c\/p\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"ab-section ab-section-soft\" aria-labelledby=\"vorteile-dts\"\u003e\n    \u003cp class=\"ab-card-label\"\u003eTechnische Einordnung\u003c\/p\u003e\n\u003ch2 id=\"vorteile-dts\"\u003eVorteile der Technologie\u003c\/h2\u003e\n    \u003cdiv class=\"ab-grid ab-grid-3\"\u003e\n\u003carticle class=\"ab-card\"\u003e\u003ch3\u003eKontinuierliches Profil\u003c\/h3\u003e\n\u003cp\u003eTemperatur wird entlang der Sensorroute statt nur an einzelnen, voneinander getrennten Punkten erfasst.\u003c\/p\u003e\u003c\/article\u003e\u003carticle class=\"ab-card\"\u003e\u003ch3\u003eLokalisierung\u003c\/h3\u003e\n\u003cp\u003eThermische Auffälligkeiten lassen sich über die Signallaufzeit einer Position entlang der Faser zuordnen.\u003c\/p\u003e\u003c\/article\u003e\u003carticle class=\"ab-card\"\u003e\u003ch3\u003ePassive Sensorfaser\u003c\/h3\u003e\n\u003cp\u003eAn den Messpositionen entlang des Kabels ist keine elektrische Versorgung für einzelne Sensoren erforderlich.\u003c\/p\u003e\u003c\/article\u003e\u003carticle class=\"ab-card\"\u003e\u003ch3\u003eElektromagnetische Immunität\u003c\/h3\u003e\n\u003cp\u003eDie optische Faser ist unempfindlich gegenüber elektromagnetischen Störungen.\u003c\/p\u003e\u003c\/article\u003e\u003carticle class=\"ab-card\"\u003e\u003ch3\u003eFlexible Alarmstrategie\u003c\/h3\u003e\n\u003cp\u003eFeste Temperatur, Anstiegsrate und Zonen können bei dafür vorgesehenen FOTAS-Plattformen Teil der Auslegung sein.\u003c\/p\u003e\u003c\/article\u003e\u003carticle class=\"ab-card\"\u003e\u003ch3\u003eProjektbezogene Skalierung\u003c\/h3\u003e\n\u003cp\u003eMessdistanz, räumliche Auflösung, Reaktionszeit und Genauigkeit hängen von Konfiguration und Anwendung ab.\u003c\/p\u003e\u003c\/article\u003e\n\u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"ab-section\" id=\"produkte\" aria-labelledby=\"produkte-dts\"\u003e\n    \u003cp class=\"ab-card-label\"\u003eAktuelles Sortiment\u003c\/p\u003e\n\u003ch2 id=\"produkte-dts\"\u003eWelche FOTAS-Produkte finden Sie in dieser Kategorie?\u003c\/h2\u003e\n    \u003cdiv class=\"ab-product-note\"\u003e\n\u003cp\u003eDie Kategorie listet zwölf DTS-Varianten. Kombiniert werden 1, 2 oder 4 Messkanäle mit nominellen Reichweiten von 2, 4, 8 oder 10 km. Für die Auswahl zählen neben Kanalzahl und Reichweite insbesondere Messaufgabe, Kabelroute, räumliche Auflösung, Reaktionszeit, Temperaturbereich und Alarmkonzept; die konkreten Werte sind dem jeweiligen Produktdatenblatt zu entnehmen.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBeispielhafte Modelle:\u003c\/strong\u003e \u003ca href=\"\/products\/fotas-dts-ch1-2km-temperatursensor\"\u003eFOTAS DTS 2 km CH1\u003c\/a\u003e · \u003ca href=\"\/products\/fotas-dts-ch4-10km-temperatursensor\"\u003eFOTAS DTS 10 km CH4\u003c\/a\u003e\u003c\/p\u003e\n\u003cp class=\"ab-note\"\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"ab-section ab-project\" aria-labelledby=\"beratung-dts\"\u003e\n    \u003cp class=\"ab-card-label\"\u003eProjektberatung\u003c\/p\u003e\n\u003ch2 id=\"beratung-dts\"\u003eWelche Lösung passt zu Ihrem Projekt?\u003c\/h2\u003e\n    \u003cp\u003eFür eine belastbare Vorauswahl sollten Anwendung, Strecke, Sensorfaser, Einbauort und Alarmprozess gemeinsam betrachtet werden.\u003c\/p\u003e\n    \u003cdiv class=\"ab-grid ab-grid-2\"\u003e\n\u003cdiv\u003e\n\u003ch3\u003eTechnische Fragen\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWelche Strecke, Fläche oder Anlage soll überwacht werden?\u003c\/li\u003e\n\u003cli\u003eWelche Ereignisse oder Veränderungen sind relevant?\u003c\/li\u003e\n\u003cli\u003eIst geeignete Glasfaser vorhanden und frei verfügbar?\u003c\/li\u003e\n\u003cli\u003eWelche Reichweite und räumliche Auflösung werden benötigt?\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch3\u003eBetrieb und Integration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eWelche Alarmierungs- und Reaktionsprozesse bestehen?\u003c\/li\u003e\n\u003cli\u003eSoll SCADA, IoT, Sicherheits- oder Leittechnik angebunden werden?\u003c\/li\u003e\n\u003cli\u003eIst die Kombination akustischer und thermischer Überwachung sinnvoll?\u003c\/li\u003e\n\u003cli\u003eWelche Umgebungs- und Zulassungsanforderungen gelten?\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n    \u003cdiv class=\"ab-buttons\"\u003e\u003ca class=\"ab-button ab-button-primary\" href=\"mailto:shop@abatec.de?subject=FOTAS%20DTS%20Projektanfrage\" target=\"_blank\" rel=\"noopener\" aria-describedby=\"a11y-new-window-message\"\u003eFOTAS-Projekt mit Abatec besprechen\u003c\/a\u003e\u003c\/div\u003e\n    \u003cp\u003e\u003ca href=\"https:\/\/abatec.de\/faseroptisches-monitoring-kritische-infrastruktur\/\" target=\"_blank\" rel=\"noopener\" aria-describedby=\"a11y-new-window-message\"\u003eFaseroptisches Monitoring für kritische Infrastruktur\u003c\/a\u003e\u003c\/p\u003e\n  \u003c\/section\u003e\n\n  \u003csection class=\"ab-section ab-faq\" aria-labelledby=\"faq-dts\"\u003e\n    \u003cp class=\"ab-card-label\"\u003eFAQ\u003c\/p\u003e\n\u003ch2 id=\"faq-dts\"\u003eHäufige Fragen zu FOTAS DTS\u003c\/h2\u003e\n\u003cdetails\u003e\u003csummary\u003eWas misst DTS tatsächlich?\u003c\/summary\u003e\u003cp\u003eDTS liefert ortsaufgelöste Temperaturwerte und daraus ein Temperaturprofil entlang der faseroptischen Sensorstrecke.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eWorin liegt der Unterschied zwischen DTS und DTGS?\u003c\/summary\u003e\u003cp\u003eDTS beantwortet primär, wie warm es an einer Position ist. DTGS legt den Schwerpunkt auf die Analyse, wie sich das thermische Verhalten über Zeit und Strecke verändert.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eKann DTS einen Brand sicher bestätigen?\u003c\/summary\u003e\u003cp\u003eDTS kann temperaturbasierte Alarmkriterien liefern. Die Einordnung als Brand und die Rolle im Brandschutzkonzept hängen von Systemausführung, Zulassung, Planung und behördlichen Anforderungen ab.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eKann vorhandene Glasfaser verwendet werden?\u003c\/summary\u003e\u003cp\u003eDas ist projektabhängig. Für verlässliche Temperaturmessung sind eine geeignete Sensorfaser, Kabelführung, thermische Kopplung und geprüfte Dämpfungswerte entscheidend.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eWelche Strecke kann ein DTS-System überwachen?\u003c\/summary\u003e\u003cp\u003eDie Reichweite ist produkt- und konfigurationsabhängig. Im aktuellen Abatec-Sortiment sind Varianten mit 2, 4, 8 und 10 km sowie unterschiedlicher Kanalzahl gelistet.\u003c\/p\u003e\u003c\/details\u003e\u003cdetails\u003e\u003csummary\u003eWas muss für die Einbindung in bestehende Systeme geklärt werden?\u003c\/summary\u003e\u003cp\u003eBenötigt werden Alarmregeln, Zonen, Datenpunkte, Schnittstellen, Protokolle, Verantwortlichkeiten und die Reaktion auf Warnungen. Diese Punkte sollten vor der Produktauswahl feststehen.\u003c\/p\u003e\u003c\/details\u003e\n  \u003c\/section\u003e\n    \u003c\/article\u003e","products":[{"product_id":"fotas-dts-ch1-2km-temperatursensor","title":"FOTAS DTS 2 km CH1 Einkanal-Temperatursensorsystem | DTS-CH1-02KM","description":"\u003cdiv data-product-description=\"fotas-dts-ch1-2km\"\u003e  \u003ch2\u003e\u003cfont color=\"#000000\"\u003eFOTAS DTS 2 km CH1 - verteilte Temperaturmessung für Brandfrüherkennung und Anlagenüberwachung\u003c\/font\u003e\u003c\/h2\u003e  \u003cp\u003eDas \u003cstrong\u003eFOTAS DTS 2 km CH1\u003c\/strong\u003e ist ein faseroptisches System für Distributed Temperature Sensing (DTS). Es erfasst Temperaturverläufe entlang eines Sensorkabels räumlich aufgelöst und eignet sich damit für die kontinuierliche thermische Überwachung ausgedehnter Anlagen und Infrastrukturen.\u003c\/p\u003e  \u003cp\u003eDie angebotene CH1-Ausführung ist für eine Konfiguration mit einen Messkanaln vorgesehen. Das offizielle FOTAS-Datenblatt führt für die 2-km-Variante Reichweiten von bis zu 2 km je Kanal sowie Gerätevarianten mit einem, zwei oder vier Kanälen auf. Dadurch lassen sich mehrere Überwachungsbereiche von einer zentralen Einheit aus erfassen.\u003c\/p\u003e  \u003ch3\u003eSo funktioniert Distributed Temperature Sensing\u003c\/h3\u003e  \u003cp\u003eDas DTS-Gerät sendet Laserlicht mit 1.550 nm in eine multimodale Glasfaser. Aus dem temperaturabhängigen rückgestreuten Licht ermittelt das System fortlaufend Temperaturwerte entlang der gesamten Messstrecke. Auf diese Weise wird das Sensorkabel zu einem linienförmigen Temperatursensor mit einem Abtastintervall von 1 m.\u003c\/p\u003e  \u003cp\u003eFür die 2-km-Ausführung nennt der Hersteller eine Temperaturauflösung von 0,1 °C bei 10 Sekunden Messzeit und eine Temperaturgenauigkeit von ±1 °C. Ein Faserbruch wird automatisch erkannt und mit einer Genauigkeit von weniger als ±5 m lokalisiert.\u003c\/p\u003e  \u003cfont color=\"#222222\"\u003e\u003cspan\u003e\u003cimg src=\"https:\/\/eu.myikas.com\/images\/2dc48198-b7a0-4f63-8807-7824d0c41208\/7e760f70-7304-42cd-8ac0-ad34b5c9c3f5\/720\/1.webp\" alt=\"FOTAS DTS CH1 Einkanal-System für verteilte Temperaturmessung bis 2 km je Kanal\" title=\"FOTAS DTS-CH1-02KM Distributed Temperature Sensing\" loading=\"lazy\"\u003e\u003c\/span\u003e\u003c\/font\u003e  \u003ch3\u003eIhre Vorteile auf einen Blick\u003c\/h3\u003e  \u003cul\u003e    \u003cli\u003e\n\u003cstrong\u003eVerteilte Messung:\u003c\/strong\u003e Temperaturdaten entlang der gesamten Glasfaser statt nur an einzelnen Messpunkten\u003c\/li\u003e    \u003cli\u003e\n\u003cstrong\u003eGroße Reichweite:\u003c\/strong\u003e bis zu 2 km je Kanal\u003c\/li\u003e    \u003cli\u003e\n\u003cstrong\u003eEinkanal-Konfiguration:\u003c\/strong\u003e mehrere Messstrecken oder Anlagenbereiche zentral überwachen\u003c\/li\u003e    \u003cli\u003e\n\u003cstrong\u003eGenaue Lokalisierung:\u003c\/strong\u003e 1 m Abtastintervall und automatische Faserbruchmeldung\u003c\/li\u003e    \u003cli\u003e\n\u003cstrong\u003eSystemintegration:\u003c\/strong\u003e Modbus TCP, Modbus RTU, Relais, Ethernet und serielle Schnittstellen\u003c\/li\u003e    \u003cli\u003e\n\u003cstrong\u003eFlexible Alarmierung:\u003c\/strong\u003e Grenzwert-, Minimum-, Temperaturanstiegs- und Abweichungsalarme\u003c\/li\u003e  \u003c\/ul\u003e  \u003ch3\u003eTypische Einsatzbereiche\u003c\/h3\u003e  \u003cul\u003e    \u003cli\u003eLineare Brandfrüherkennung in Straßen-, Bahn- und Versorgungstunneln\u003c\/li\u003e    \u003cli\u003eThermische Überwachung von Energie- und Leistungskabeln\u003c\/li\u003e    \u003cli\u003eTemperaturüberwachung in Industrieanlagen, Lagern und Rechenzentren\u003c\/li\u003e    \u003cli\u003eErkennung thermischer Auffälligkeiten entlang von Rohrleitungen und technischen Trassen\u003c\/li\u003e    \u003cli\u003eZonenbasierte Überwachung komplexer Infrastrukturprojekte\u003c\/li\u003e  \u003c\/ul\u003e  \u003ch3\u003eTechnische Highlights\u003c\/h3\u003e  \u003cdiv\u003e    \u003ctable\u003e      \u003ctbody\u003e        \u003ctr\u003e\n\u003cth\u003eArtikelnummer \/ Ausführung\u003c\/th\u003e\n\u003ctd\u003eDTS-CH1-02KM \/ CH1\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eSensortechnologie\u003c\/th\u003e\n\u003ctd\u003eDistributed Temperature Sensing (DTS)\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eReichweite\u003c\/th\u003e\n\u003ctd\u003eBis zu 2 km je Kanal\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eKanaloptionen laut Hersteller\u003c\/th\u003e\n\u003ctd\u003e1 \/ 2 \/ 4; Shopausführung CH1\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eAbtastintervall\u003c\/th\u003e\n\u003ctd\u003e1 m\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eTemperaturauflösung bei 2 km\u003c\/th\u003e\n\u003ctd\u003e0,1 °C bei 10 s\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eTemperaturgenauigkeit\u003c\/th\u003e\n\u003ctd\u003e±1 °C\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eMesszeit\u003c\/th\u003e\n\u003ctd\u003eTypisch ca. 5 s bei linearen Wärmeanwendungen (Herstellerangabe mit Bezug auf EN 54-22)\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eFaserbruchalarm\u003c\/th\u003e\n\u003ctd\u003eAutomatische Erkennung, Ortungsgenauigkeit \u0026lt; ±5 m\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eMessbarer Temperaturbereich\u003c\/th\u003e\n\u003ctd\u003e-220 bis +800 °C, abhängig vom eingesetzten faseroptischen Sensorkabel\u003c\/td\u003e\n\u003c\/tr\u003e      \u003c\/tbody\u003e    \u003c\/table\u003e  \u003c\/div\u003e  \u003ch3\u003eOptische, elektrische und mechanische Daten\u003c\/h3\u003e  \u003cdiv\u003e    \u003ctable\u003e      \u003ctbody\u003e        \u003ctr\u003e\n\u003cth\u003eLaserwellenlänge\u003c\/th\u003e\n\u003ctd\u003e1.550 nm\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eOptisches Budget\u003c\/th\u003e\n\u003ctd\u003e10 dB\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eAnschluss \/ Fasertyp\u003c\/th\u003e\n\u003ctd\u003eE2000 \/ Multimode 62,5\/125\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eLasersicherheitsklasse\u003c\/th\u003e\n\u003ctd\u003eKlasse 1\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eVersorgung \/ Leistungsaufnahme\u003c\/th\u003e\n\u003ctd\u003e24 V DC \/ maximal 85 W\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eBauform \/ Schutzart\u003c\/th\u003e\n\u003ctd\u003e3 HE \/ IP40\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eAbmessungen (B × H × T)\u003c\/th\u003e\n\u003ctd\u003e485 × 133 × 509 mm\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eNettogewicht\u003c\/th\u003e\n\u003ctd\u003e10 kg\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eGehäuse\u003c\/th\u003e\n\u003ctd\u003eLackierter verzinkter Stahl, mattschwarz\u003c\/td\u003e\n\u003c\/tr\u003e      \u003c\/tbody\u003e    \u003c\/table\u003e  \u003c\/div\u003e  \u003ch3\u003eSchnittstellen, Alarmierung und Software\u003c\/h3\u003e  \u003cul\u003e    \u003cli\u003e48 NO\/NC-Relaiskontakte\u003c\/li\u003e    \u003cli\u003eModbus TCP und Modbus RTU\u003c\/li\u003e    \u003cli\u003e1 × RJ45 mit 100 Mbit\/s\u003c\/li\u003e    \u003cli\u003e1 × RS-485, 1 × RS-232 und 1 × USB\u003c\/li\u003e    \u003cli\u003e7-Zoll-Touchscreen mit 1.024 × 600 Pixeln\u003c\/li\u003e    \u003cli\u003eInterner Speicher für mehr als 500.000 Messungen bei 10 km (Hersteller-Benchmark)\u003c\/li\u003e    \u003cli\u003eFOTAS Web mit bis zu 1.000 Zonen und Alarmen für Maximum, Minimum, Anstiegsrate und Abweichung\u003c\/li\u003e  \u003c\/ul\u003e  \u003ch3\u003eUmgebungsbedingungen\u003c\/h3\u003e  \u003cdiv\u003e    \u003ctable\u003e      \u003ctbody\u003e        \u003ctr\u003e\n\u003cth\u003eBetriebstemperatur\u003c\/th\u003e\n\u003ctd\u003e-10 bis +55 °C\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eBetriebsfeuchte\u003c\/th\u003e\n\u003ctd\u003e0 bis 95 % r. F.\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eLagertemperatur\u003c\/th\u003e\n\u003ctd\u003e-10 bis +85 °C\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eLagerfeuchte\u003c\/th\u003e\n\u003ctd\u003e0 bis 95 % r. F., nicht kondensierend\u003c\/td\u003e\n\u003c\/tr\u003e      \u003c\/tbody\u003e    \u003c\/table\u003e  \u003c\/div\u003e  \u003cdiv\u003e    \u003ch3\u003eDTS-System für Ihr Projekt auslegen\u003c\/h3\u003e    \u003cp\u003eFür eine belastbare Systemauswahl müssen Reichweite, Anzahl und Führung der Messkanäle, Sensorkabel, Temperaturbereich, Alarmzonen sowie die Einbindung in Brandmelde-, Leit- oder Automatisierungssysteme gemeinsam betrachtet werden.\u003c\/p\u003e    \u003cp\u003e\u003ca href=\"https:\/\/shop.abatec.de\/pages\/kontakt\"\u003eSprechen Sie mit abatec über Ihre DTS-Anwendung und die technische Projektierung.\u003c\/a\u003e\u003c\/p\u003e  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"FOTAS","offers":[{"title":"Default Title","offer_id":67581850386822,"sku":"DTS-CH1-02KM","price":22124.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1111\/8768\/9862\/files\/image_1950_d2d125e7-9f72-44e1-ae8a-d41543bd82ba.webp?v=1791369194"},{"product_id":"fotas-dts-ch1-4km-temperatursensor","title":"FOTAS DTS 4 km CH1 Einkanal-Temperatursensorsystem | DTS-CH1-04KM","description":"\u003cdiv data-product-description=\"fotas-dts-ch1-4km\"\u003e  \u003ch2\u003e\u003cfont color=\"#000000\"\u003eFOTAS DTS 4 km CH1 - verteilte Temperaturmessung für Brandfrüherkennung und Anlagenüberwachung\u003c\/font\u003e\u003c\/h2\u003e  \u003cp\u003eDas \u003cstrong\u003eFOTAS DTS 4 km CH1\u003c\/strong\u003e ist ein faseroptisches System für Distributed Temperature Sensing (DTS). Es erfasst Temperaturverläufe entlang eines Sensorkabels räumlich aufgelöst und eignet sich damit für die kontinuierliche thermische Überwachung ausgedehnter Anlagen und Infrastrukturen.\u003c\/p\u003e  \u003cp\u003eDie angebotene CH1-Ausführung ist für eine Konfiguration mit einen Messkanaln vorgesehen. Das offizielle FOTAS-Datenblatt führt für die 4-km-Variante Reichweiten von bis zu 4 km je Kanal sowie Gerätevarianten mit einem, zwei oder vier Kanälen auf. Dadurch lassen sich mehrere Überwachungsbereiche von einer zentralen Einheit aus erfassen.\u003c\/p\u003e  \u003ch3\u003eSo funktioniert Distributed Temperature Sensing\u003c\/h3\u003e  \u003cp\u003eDas DTS-Gerät sendet Laserlicht mit 1.550 nm in eine multimodale Glasfaser. Aus dem temperaturabhängigen rückgestreuten Licht ermittelt das System fortlaufend Temperaturwerte entlang der gesamten Messstrecke. Auf diese Weise wird das Sensorkabel zu einem linienförmigen Temperatursensor mit einem Abtastintervall von 1 m.\u003c\/p\u003e  \u003cp\u003eFür die 4-km-Ausführung nennt der Hersteller eine Temperaturauflösung von 0,1 °C bei 10 Sekunden Messzeit und eine Temperaturgenauigkeit von ±1 °C. Ein Faserbruch wird automatisch erkannt und mit einer Genauigkeit von weniger als ±5 m lokalisiert.\u003c\/p\u003e  \u003cfont color=\"#222222\"\u003e\u003cspan\u003e\u003cimg src=\"https:\/\/eu.myikas.com\/images\/2dc48198-b7a0-4f63-8807-7824d0c41208\/2a73a070-a6e6-4c49-a6d2-5323b407ff9e\/720\/1.webp\" alt=\"FOTAS DTS CH1 Einkanal-System für verteilte Temperaturmessung bis 4 km je Kanal\" title=\"FOTAS DTS-CH1-04KM Distributed Temperature Sensing\" loading=\"lazy\"\u003e\u003c\/span\u003e\u003c\/font\u003e  \u003ch3\u003eIhre Vorteile auf einen Blick\u003c\/h3\u003e  \u003cul\u003e    \u003cli\u003e\n\u003cstrong\u003eVerteilte Messung:\u003c\/strong\u003e Temperaturdaten entlang der gesamten Glasfaser statt nur an einzelnen Messpunkten\u003c\/li\u003e    \u003cli\u003e\n\u003cstrong\u003eGroße Reichweite:\u003c\/strong\u003e bis zu 4 km je Kanal\u003c\/li\u003e    \u003cli\u003e\n\u003cstrong\u003eEinkanal-Konfiguration:\u003c\/strong\u003e mehrere Messstrecken oder Anlagenbereiche zentral überwachen\u003c\/li\u003e    \u003cli\u003e\n\u003cstrong\u003eGenaue Lokalisierung:\u003c\/strong\u003e 1 m Abtastintervall und automatische Faserbruchmeldung\u003c\/li\u003e    \u003cli\u003e\n\u003cstrong\u003eSystemintegration:\u003c\/strong\u003e Modbus TCP, Modbus RTU, Relais, Ethernet und serielle Schnittstellen\u003c\/li\u003e    \u003cli\u003e\n\u003cstrong\u003eFlexible Alarmierung:\u003c\/strong\u003e Grenzwert-, Minimum-, Temperaturanstiegs- und Abweichungsalarme\u003c\/li\u003e  \u003c\/ul\u003e  \u003ch3\u003eTypische Einsatzbereiche\u003c\/h3\u003e  \u003cul\u003e    \u003cli\u003eLineare Brandfrüherkennung in Straßen-, Bahn- und Versorgungstunneln\u003c\/li\u003e    \u003cli\u003eThermische Überwachung von Energie- und Leistungskabeln\u003c\/li\u003e    \u003cli\u003eTemperaturüberwachung in Industrieanlagen, Lagern und Rechenzentren\u003c\/li\u003e    \u003cli\u003eErkennung thermischer Auffälligkeiten entlang von Rohrleitungen und technischen Trassen\u003c\/li\u003e    \u003cli\u003eZonenbasierte Überwachung komplexer Infrastrukturprojekte\u003c\/li\u003e  \u003c\/ul\u003e  \u003ch3\u003eTechnische Highlights\u003c\/h3\u003e  \u003cdiv\u003e    \u003ctable\u003e      \u003ctbody\u003e        \u003ctr\u003e\n\u003cth\u003eArtikelnummer \/ Ausführung\u003c\/th\u003e\n\u003ctd\u003eDTS-CH1-04KM \/ CH1\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eSensortechnologie\u003c\/th\u003e\n\u003ctd\u003eDistributed Temperature Sensing (DTS)\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eReichweite\u003c\/th\u003e\n\u003ctd\u003eBis zu 4 km je Kanal\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eKanaloptionen laut Hersteller\u003c\/th\u003e\n\u003ctd\u003e1 \/ 2 \/ 4; Shopausführung CH1\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eAbtastintervall\u003c\/th\u003e\n\u003ctd\u003e1 m\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eTemperaturauflösung bei 4 km\u003c\/th\u003e\n\u003ctd\u003e0,1 °C bei 10 s\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eTemperaturgenauigkeit\u003c\/th\u003e\n\u003ctd\u003e±1 °C\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eMesszeit\u003c\/th\u003e\n\u003ctd\u003eTypisch ca. 5 s bei linearen Wärmeanwendungen (Herstellerangabe mit Bezug auf EN 54-22)\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eFaserbruchalarm\u003c\/th\u003e\n\u003ctd\u003eAutomatische Erkennung, Ortungsgenauigkeit \u0026lt; ±5 m\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eMessbarer Temperaturbereich\u003c\/th\u003e\n\u003ctd\u003e-220 bis +800 °C, abhängig vom eingesetzten faseroptischen Sensorkabel\u003c\/td\u003e\n\u003c\/tr\u003e      \u003c\/tbody\u003e    \u003c\/table\u003e  \u003c\/div\u003e  \u003ch3\u003eOptische, elektrische und mechanische Daten\u003c\/h3\u003e  \u003cdiv\u003e    \u003ctable\u003e      \u003ctbody\u003e        \u003ctr\u003e\n\u003cth\u003eLaserwellenlänge\u003c\/th\u003e\n\u003ctd\u003e1.550 nm\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eOptisches Budget\u003c\/th\u003e\n\u003ctd\u003e10 dB\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eAnschluss \/ Fasertyp\u003c\/th\u003e\n\u003ctd\u003eE2000 \/ Multimode 62,5\/125\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eLasersicherheitsklasse\u003c\/th\u003e\n\u003ctd\u003eKlasse 1\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eVersorgung \/ Leistungsaufnahme\u003c\/th\u003e\n\u003ctd\u003e24 V DC \/ maximal 85 W\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eBauform \/ Schutzart\u003c\/th\u003e\n\u003ctd\u003e3 HE \/ IP40\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eAbmessungen (B × H × T)\u003c\/th\u003e\n\u003ctd\u003e485 × 133 × 509 mm\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eNettogewicht\u003c\/th\u003e\n\u003ctd\u003e10 kg\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eGehäuse\u003c\/th\u003e\n\u003ctd\u003eLackierter verzinkter Stahl, mattschwarz\u003c\/td\u003e\n\u003c\/tr\u003e      \u003c\/tbody\u003e    \u003c\/table\u003e  \u003c\/div\u003e  \u003ch3\u003eSchnittstellen, Alarmierung und Software\u003c\/h3\u003e  \u003cul\u003e    \u003cli\u003e48 NO\/NC-Relaiskontakte\u003c\/li\u003e    \u003cli\u003eModbus TCP und Modbus RTU\u003c\/li\u003e    \u003cli\u003e1 × RJ45 mit 100 Mbit\/s\u003c\/li\u003e    \u003cli\u003e1 × RS-485, 1 × RS-232 und 1 × USB\u003c\/li\u003e    \u003cli\u003e7-Zoll-Touchscreen mit 1.024 × 600 Pixeln\u003c\/li\u003e    \u003cli\u003eInterner Speicher für mehr als 500.000 Messungen bei 10 km (Hersteller-Benchmark)\u003c\/li\u003e    \u003cli\u003eFOTAS Web mit bis zu 1.000 Zonen und Alarmen für Maximum, Minimum, Anstiegsrate und Abweichung\u003c\/li\u003e  \u003c\/ul\u003e  \u003ch3\u003eUmgebungsbedingungen\u003c\/h3\u003e  \u003cdiv\u003e    \u003ctable\u003e      \u003ctbody\u003e        \u003ctr\u003e\n\u003cth\u003eBetriebstemperatur\u003c\/th\u003e\n\u003ctd\u003e-10 bis +55 °C\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eBetriebsfeuchte\u003c\/th\u003e\n\u003ctd\u003e0 bis 95 % r. F.\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eLagertemperatur\u003c\/th\u003e\n\u003ctd\u003e-10 bis +85 °C\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eLagerfeuchte\u003c\/th\u003e\n\u003ctd\u003e0 bis 95 % r. F., nicht kondensierend\u003c\/td\u003e\n\u003c\/tr\u003e      \u003c\/tbody\u003e    \u003c\/table\u003e  \u003c\/div\u003e  \u003cdiv\u003e    \u003ch3\u003eDTS-System für Ihr Projekt auslegen\u003c\/h3\u003e    \u003cp\u003eFür eine belastbare Systemauswahl müssen Reichweite, Anzahl und Führung der Messkanäle, Sensorkabel, Temperaturbereich, Alarmzonen sowie die Einbindung in Brandmelde-, Leit- oder Automatisierungssysteme gemeinsam betrachtet werden.\u003c\/p\u003e    \u003cp\u003e\u003ca href=\"https:\/\/shop.abatec.de\/pages\/kontakt\"\u003eSprechen Sie mit abatec über Ihre DTS-Anwendung und die technische Projektierung.\u003c\/a\u003e\u003c\/p\u003e  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"FOTAS","offers":[{"title":"Default Title","offer_id":67581902684550,"sku":"DTS-CH1-04KM","price":23547.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1111\/8768\/9862\/files\/image_1950_8dd29ba7-f466-46fc-b3f4-88d3585d7d42.webp?v=1791369903"},{"product_id":"fotas-dts-ch1-8km-temperatursensor","title":"FOTAS DTS 8 km CH1 Einkanal-Temperatursensorsystem | DTS-CH1-08KM","description":"\u003cdiv data-product-description=\"fotas-dts-ch1-8km\"\u003e  \u003ch2\u003e\u003cfont color=\"#000000\"\u003eFOTAS DTS 8 km CH1 - verteilte Temperaturmessung für Brandfrüherkennung und Anlagenüberwachung\u003c\/font\u003e\u003c\/h2\u003e  \u003cp\u003eDas \u003cstrong\u003eFOTAS DTS 8 km CH1\u003c\/strong\u003e ist ein faseroptisches System für Distributed Temperature Sensing (DTS). Es erfasst Temperaturverläufe entlang eines Sensorkabels räumlich aufgelöst und eignet sich damit für die kontinuierliche thermische Überwachung ausgedehnter Anlagen und Infrastrukturen.\u003c\/p\u003e  \u003cp\u003eDie angebotene CH1-Ausführung ist für eine Konfiguration mit einen Messkanaln vorgesehen. Das offizielle FOTAS-Datenblatt führt für die 8-km-Variante Reichweiten von bis zu 8 km je Kanal sowie Gerätevarianten mit einem, zwei oder vier Kanälen auf. Dadurch lassen sich mehrere Überwachungsbereiche von einer zentralen Einheit aus erfassen.\u003c\/p\u003e  \u003ch3\u003eSo funktioniert Distributed Temperature Sensing\u003c\/h3\u003e  \u003cp\u003eDas DTS-Gerät sendet Laserlicht mit 1.550 nm in eine multimodale Glasfaser. Aus dem temperaturabhängigen rückgestreuten Licht ermittelt das System fortlaufend Temperaturwerte entlang der gesamten Messstrecke. Auf diese Weise wird das Sensorkabel zu einem linienförmigen Temperatursensor mit einem Abtastintervall von 1 m.\u003c\/p\u003e  \u003cp\u003eFür die 8-km-Ausführung nennt der Hersteller eine Temperaturauflösung von 0,3 °C bei 10 Sekunden Messzeit und eine Temperaturgenauigkeit von ±1 °C. Ein Faserbruch wird automatisch erkannt und mit einer Genauigkeit von weniger als ±5 m lokalisiert.\u003c\/p\u003e  \u003cfont color=\"#222222\"\u003e\u003cspan\u003e\u003cimg src=\"https:\/\/eu.myikas.com\/images\/2dc48198-b7a0-4f63-8807-7824d0c41208\/8a2fee97-e5c0-4cb1-adc2-f527778bd12a\/720\/1.webp\" alt=\"FOTAS DTS CH1 Einkanal-System für verteilte Temperaturmessung bis 8 km je Kanal\" title=\"FOTAS DTS-CH1-08KM Distributed Temperature Sensing\" loading=\"lazy\"\u003e\u003c\/span\u003e\u003c\/font\u003e  \u003ch3\u003eIhre Vorteile auf einen Blick\u003c\/h3\u003e  \u003cul\u003e    \u003cli\u003e\n\u003cstrong\u003eVerteilte Messung:\u003c\/strong\u003e Temperaturdaten entlang der gesamten Glasfaser statt nur an einzelnen Messpunkten\u003c\/li\u003e    \u003cli\u003e\n\u003cstrong\u003eGroße Reichweite:\u003c\/strong\u003e bis zu 8 km je Kanal\u003c\/li\u003e    \u003cli\u003e\n\u003cstrong\u003eEinkanal-Konfiguration:\u003c\/strong\u003e mehrere Messstrecken oder Anlagenbereiche zentral überwachen\u003c\/li\u003e    \u003cli\u003e\n\u003cstrong\u003eGenaue Lokalisierung:\u003c\/strong\u003e 1 m Abtastintervall und automatische Faserbruchmeldung\u003c\/li\u003e    \u003cli\u003e\n\u003cstrong\u003eSystemintegration:\u003c\/strong\u003e Modbus TCP, Modbus RTU, Relais, Ethernet und serielle Schnittstellen\u003c\/li\u003e    \u003cli\u003e\n\u003cstrong\u003eFlexible Alarmierung:\u003c\/strong\u003e Grenzwert-, Minimum-, Temperaturanstiegs- und Abweichungsalarme\u003c\/li\u003e  \u003c\/ul\u003e  \u003ch3\u003eTypische Einsatzbereiche\u003c\/h3\u003e  \u003cul\u003e    \u003cli\u003eLineare Brandfrüherkennung in Straßen-, Bahn- und Versorgungstunneln\u003c\/li\u003e    \u003cli\u003eThermische Überwachung von Energie- und Leistungskabeln\u003c\/li\u003e    \u003cli\u003eTemperaturüberwachung in Industrieanlagen, Lagern und Rechenzentren\u003c\/li\u003e    \u003cli\u003eErkennung thermischer Auffälligkeiten entlang von Rohrleitungen und technischen Trassen\u003c\/li\u003e    \u003cli\u003eZonenbasierte Überwachung komplexer Infrastrukturprojekte\u003c\/li\u003e  \u003c\/ul\u003e  \u003ch3\u003eTechnische Highlights\u003c\/h3\u003e  \u003cdiv\u003e    \u003ctable\u003e      \u003ctbody\u003e        \u003ctr\u003e\n\u003cth\u003eArtikelnummer \/ Ausführung\u003c\/th\u003e\n\u003ctd\u003eDTS-CH1-08KM \/ CH1\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eSensortechnologie\u003c\/th\u003e\n\u003ctd\u003eDistributed Temperature Sensing (DTS)\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eReichweite\u003c\/th\u003e\n\u003ctd\u003eBis zu 8 km je Kanal\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eKanaloptionen laut Hersteller\u003c\/th\u003e\n\u003ctd\u003e1 \/ 2 \/ 4; Shopausführung CH1\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eAbtastintervall\u003c\/th\u003e\n\u003ctd\u003e1 m\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eTemperaturauflösung bei 8 km\u003c\/th\u003e\n\u003ctd\u003e0,3 °C bei 10 s\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eTemperaturgenauigkeit\u003c\/th\u003e\n\u003ctd\u003e±1 °C\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eMesszeit\u003c\/th\u003e\n\u003ctd\u003eTypisch ca. 5 s bei linearen Wärmeanwendungen (Herstellerangabe mit Bezug auf EN 54-22)\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eFaserbruchalarm\u003c\/th\u003e\n\u003ctd\u003eAutomatische Erkennung, Ortungsgenauigkeit \u0026lt; ±5 m\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eMessbarer Temperaturbereich\u003c\/th\u003e\n\u003ctd\u003e-220 bis +800 °C, abhängig vom eingesetzten faseroptischen Sensorkabel\u003c\/td\u003e\n\u003c\/tr\u003e      \u003c\/tbody\u003e    \u003c\/table\u003e  \u003c\/div\u003e  \u003ch3\u003eOptische, elektrische und mechanische Daten\u003c\/h3\u003e  \u003cdiv\u003e    \u003ctable\u003e      \u003ctbody\u003e        \u003ctr\u003e\n\u003cth\u003eLaserwellenlänge\u003c\/th\u003e\n\u003ctd\u003e1.550 nm\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eOptisches Budget\u003c\/th\u003e\n\u003ctd\u003e10 dB\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eAnschluss \/ Fasertyp\u003c\/th\u003e\n\u003ctd\u003eE2000 \/ Multimode 62,5\/125\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eLasersicherheitsklasse\u003c\/th\u003e\n\u003ctd\u003eKlasse 1\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eVersorgung \/ Leistungsaufnahme\u003c\/th\u003e\n\u003ctd\u003e24 V DC \/ maximal 85 W\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eBauform \/ Schutzart\u003c\/th\u003e\n\u003ctd\u003e3 HE \/ IP40\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eAbmessungen (B × H × T)\u003c\/th\u003e\n\u003ctd\u003e485 × 133 × 509 mm\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eNettogewicht\u003c\/th\u003e\n\u003ctd\u003e10 kg\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eGehäuse\u003c\/th\u003e\n\u003ctd\u003eLackierter verzinkter Stahl, mattschwarz\u003c\/td\u003e\n\u003c\/tr\u003e      \u003c\/tbody\u003e    \u003c\/table\u003e  \u003c\/div\u003e  \u003ch3\u003eSchnittstellen, Alarmierung und Software\u003c\/h3\u003e  \u003cul\u003e    \u003cli\u003e48 NO\/NC-Relaiskontakte\u003c\/li\u003e    \u003cli\u003eModbus TCP und Modbus RTU\u003c\/li\u003e    \u003cli\u003e1 × RJ45 mit 100 Mbit\/s\u003c\/li\u003e    \u003cli\u003e1 × RS-485, 1 × RS-232 und 1 × USB\u003c\/li\u003e    \u003cli\u003e7-Zoll-Touchscreen mit 1.024 × 600 Pixeln\u003c\/li\u003e    \u003cli\u003eInterner Speicher für mehr als 500.000 Messungen bei 10 km (Hersteller-Benchmark)\u003c\/li\u003e    \u003cli\u003eFOTAS Web mit bis zu 1.000 Zonen und Alarmen für Maximum, Minimum, Anstiegsrate und Abweichung\u003c\/li\u003e  \u003c\/ul\u003e  \u003ch3\u003eUmgebungsbedingungen\u003c\/h3\u003e  \u003cdiv\u003e    \u003ctable\u003e      \u003ctbody\u003e        \u003ctr\u003e\n\u003cth\u003eBetriebstemperatur\u003c\/th\u003e\n\u003ctd\u003e-10 bis +55 °C\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eBetriebsfeuchte\u003c\/th\u003e\n\u003ctd\u003e0 bis 95 % r. F.\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eLagertemperatur\u003c\/th\u003e\n\u003ctd\u003e-10 bis +85 °C\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eLagerfeuchte\u003c\/th\u003e\n\u003ctd\u003e0 bis 95 % r. F., nicht kondensierend\u003c\/td\u003e\n\u003c\/tr\u003e      \u003c\/tbody\u003e    \u003c\/table\u003e  \u003c\/div\u003e  \u003cdiv\u003e    \u003ch3\u003eDTS-System für Ihr Projekt auslegen\u003c\/h3\u003e    \u003cp\u003eFür eine belastbare Systemauswahl müssen Reichweite, Anzahl und Führung der Messkanäle, Sensorkabel, Temperaturbereich, Alarmzonen sowie die Einbindung in Brandmelde-, Leit- oder Automatisierungssysteme gemeinsam betrachtet werden.\u003c\/p\u003e    \u003cp\u003e\u003ca href=\"https:\/\/shop.abatec.de\/pages\/kontakt\"\u003eSprechen Sie mit abatec über Ihre DTS-Anwendung und die technische Projektierung.\u003c\/a\u003e\u003c\/p\u003e  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"FOTAS","offers":[{"title":"Default Title","offer_id":67581902750086,"sku":"DTS-CH1-08KM","price":25100.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1111\/8768\/9862\/files\/image_1950_e5ba0a63-8b95-44de-91a1-d900653e62b2.webp?v=1791369904"},{"product_id":"fotas-dts-ch1-10km-temperatursensor","title":"FOTAS DTS 10 km CH1 Einkanal-Temperatursensorsystem | DTS-CH1-10KM","description":"\u003cdiv data-product-description=\"fotas-dts-ch1-10km\"\u003e  \u003ch2\u003e\u003cfont color=\"#000000\"\u003eFOTAS DTS 10 km CH1 - verteilte Temperaturmessung für Brandfrüherkennung und Anlagenüberwachung\u003c\/font\u003e\u003c\/h2\u003e  \u003cp\u003eDas \u003cstrong\u003eFOTAS DTS 10 km CH1\u003c\/strong\u003e ist ein faseroptisches System für Distributed Temperature Sensing (DTS). Es erfasst Temperaturverläufe entlang eines Sensorkabels räumlich aufgelöst und eignet sich damit für die kontinuierliche thermische Überwachung ausgedehnter Anlagen und Infrastrukturen.\u003c\/p\u003e  \u003cp\u003eDie angebotene CH1-Ausführung ist für eine Konfiguration mit einen Messkanaln vorgesehen. Das offizielle FOTAS-Datenblatt führt für die 10-km-Variante Reichweiten von bis zu 10 km je Kanal sowie Gerätevarianten mit einem, zwei oder vier Kanälen auf. Dadurch lassen sich mehrere Überwachungsbereiche von einer zentralen Einheit aus erfassen.\u003c\/p\u003e  \u003ch3\u003eSo funktioniert Distributed Temperature Sensing\u003c\/h3\u003e  \u003cp\u003eDas DTS-Gerät sendet Laserlicht mit 1.550 nm in eine multimodale Glasfaser. Aus dem temperaturabhängigen rückgestreuten Licht ermittelt das System fortlaufend Temperaturwerte entlang der gesamten Messstrecke. Auf diese Weise wird das Sensorkabel zu einem linienförmigen Temperatursensor mit einem Abtastintervall von 1 m.\u003c\/p\u003e  \u003cp\u003eFür die 10-km-Ausführung nennt der Hersteller eine Temperaturauflösung von 0,3 °C bei 10 Sekunden Messzeit und eine Temperaturgenauigkeit von ±1 °C. Ein Faserbruch wird automatisch erkannt und mit einer Genauigkeit von weniger als ±5 m lokalisiert.\u003c\/p\u003e  \u003cfont color=\"#222222\"\u003e\u003cspan\u003e\u003cimg src=\"https:\/\/eu.myikas.com\/images\/2dc48198-b7a0-4f63-8807-7824d0c41208\/80fc7479-5550-4470-96c1-409c332c1535\/720\/1.webp\" alt=\"FOTAS DTS CH1 Einkanal-System für verteilte Temperaturmessung bis 10 km je Kanal\" title=\"FOTAS DTS-CH1-10KM Distributed Temperature Sensing\" loading=\"lazy\"\u003e\u003c\/span\u003e\u003c\/font\u003e  \u003ch3\u003eIhre Vorteile auf einen Blick\u003c\/h3\u003e  \u003cul\u003e    \u003cli\u003e\n\u003cstrong\u003eVerteilte Messung:\u003c\/strong\u003e Temperaturdaten entlang der gesamten Glasfaser statt nur an einzelnen Messpunkten\u003c\/li\u003e    \u003cli\u003e\n\u003cstrong\u003eGroße Reichweite:\u003c\/strong\u003e bis zu 10 km je Kanal\u003c\/li\u003e    \u003cli\u003e\n\u003cstrong\u003eEinkanal-Konfiguration:\u003c\/strong\u003e mehrere Messstrecken oder Anlagenbereiche zentral überwachen\u003c\/li\u003e    \u003cli\u003e\n\u003cstrong\u003eGenaue Lokalisierung:\u003c\/strong\u003e 1 m Abtastintervall und automatische Faserbruchmeldung\u003c\/li\u003e    \u003cli\u003e\n\u003cstrong\u003eSystemintegration:\u003c\/strong\u003e Modbus TCP, Modbus RTU, Relais, Ethernet und serielle Schnittstellen\u003c\/li\u003e    \u003cli\u003e\n\u003cstrong\u003eFlexible Alarmierung:\u003c\/strong\u003e Grenzwert-, Minimum-, Temperaturanstiegs- und Abweichungsalarme\u003c\/li\u003e  \u003c\/ul\u003e  \u003ch3\u003eTypische Einsatzbereiche\u003c\/h3\u003e  \u003cul\u003e    \u003cli\u003eLineare Brandfrüherkennung in Straßen-, Bahn- und Versorgungstunneln\u003c\/li\u003e    \u003cli\u003eThermische Überwachung von Energie- und Leistungskabeln\u003c\/li\u003e    \u003cli\u003eTemperaturüberwachung in Industrieanlagen, Lagern und Rechenzentren\u003c\/li\u003e    \u003cli\u003eErkennung thermischer Auffälligkeiten entlang von Rohrleitungen und technischen Trassen\u003c\/li\u003e    \u003cli\u003eZonenbasierte Überwachung komplexer Infrastrukturprojekte\u003c\/li\u003e  \u003c\/ul\u003e  \u003ch3\u003eTechnische Highlights\u003c\/h3\u003e  \u003cdiv\u003e    \u003ctable\u003e      \u003ctbody\u003e        \u003ctr\u003e\n\u003cth\u003eArtikelnummer \/ Ausführung\u003c\/th\u003e\n\u003ctd\u003eDTS-CH1-10KM \/ CH1\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eSensortechnologie\u003c\/th\u003e\n\u003ctd\u003eDistributed Temperature Sensing (DTS)\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eReichweite\u003c\/th\u003e\n\u003ctd\u003eBis zu 10 km je Kanal\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eKanaloptionen laut Hersteller\u003c\/th\u003e\n\u003ctd\u003e1 \/ 2 \/ 4; Shopausführung CH1\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eAbtastintervall\u003c\/th\u003e\n\u003ctd\u003e1 m\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eTemperaturauflösung bei 10 km\u003c\/th\u003e\n\u003ctd\u003e0,3 °C bei 10 s\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eTemperaturgenauigkeit\u003c\/th\u003e\n\u003ctd\u003e±1 °C\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eMesszeit\u003c\/th\u003e\n\u003ctd\u003eTypisch ca. 5 s bei linearen Wärmeanwendungen (Herstellerangabe mit Bezug auf EN 54-22)\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eFaserbruchalarm\u003c\/th\u003e\n\u003ctd\u003eAutomatische Erkennung, Ortungsgenauigkeit \u0026lt; ±5 m\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eMessbarer Temperaturbereich\u003c\/th\u003e\n\u003ctd\u003e-220 bis +800 °C, abhängig vom eingesetzten faseroptischen Sensorkabel\u003c\/td\u003e\n\u003c\/tr\u003e      \u003c\/tbody\u003e    \u003c\/table\u003e  \u003c\/div\u003e  \u003ch3\u003eOptische, elektrische und mechanische Daten\u003c\/h3\u003e  \u003cdiv\u003e    \u003ctable\u003e      \u003ctbody\u003e        \u003ctr\u003e\n\u003cth\u003eLaserwellenlänge\u003c\/th\u003e\n\u003ctd\u003e1.550 nm\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eOptisches Budget\u003c\/th\u003e\n\u003ctd\u003e10 dB\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eAnschluss \/ Fasertyp\u003c\/th\u003e\n\u003ctd\u003eE2000 \/ Multimode 62,5\/125\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eLasersicherheitsklasse\u003c\/th\u003e\n\u003ctd\u003eKlasse 1\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eVersorgung \/ Leistungsaufnahme\u003c\/th\u003e\n\u003ctd\u003e24 V DC \/ maximal 85 W\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eBauform \/ Schutzart\u003c\/th\u003e\n\u003ctd\u003e3 HE \/ IP40\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eAbmessungen (B × H × T)\u003c\/th\u003e\n\u003ctd\u003e485 × 133 × 509 mm\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eNettogewicht\u003c\/th\u003e\n\u003ctd\u003e10 kg\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eGehäuse\u003c\/th\u003e\n\u003ctd\u003eLackierter verzinkter Stahl, mattschwarz\u003c\/td\u003e\n\u003c\/tr\u003e      \u003c\/tbody\u003e    \u003c\/table\u003e  \u003c\/div\u003e  \u003ch3\u003eSchnittstellen, Alarmierung und Software\u003c\/h3\u003e  \u003cul\u003e    \u003cli\u003e48 NO\/NC-Relaiskontakte\u003c\/li\u003e    \u003cli\u003eModbus TCP und Modbus RTU\u003c\/li\u003e    \u003cli\u003e1 × RJ45 mit 100 Mbit\/s\u003c\/li\u003e    \u003cli\u003e1 × RS-485, 1 × RS-232 und 1 × USB\u003c\/li\u003e    \u003cli\u003e7-Zoll-Touchscreen mit 1.024 × 600 Pixeln\u003c\/li\u003e    \u003cli\u003eInterner Speicher für mehr als 500.000 Messungen bei 10 km\u003c\/li\u003e    \u003cli\u003eFOTAS Web mit bis zu 1.000 Zonen und Alarmen für Maximum, Minimum, Anstiegsrate und Abweichung\u003c\/li\u003e  \u003c\/ul\u003e  \u003ch3\u003eUmgebungsbedingungen\u003c\/h3\u003e  \u003cdiv\u003e    \u003ctable\u003e      \u003ctbody\u003e        \u003ctr\u003e\n\u003cth\u003eBetriebstemperatur\u003c\/th\u003e\n\u003ctd\u003e-10 bis +55 °C\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eBetriebsfeuchte\u003c\/th\u003e\n\u003ctd\u003e0 bis 95 % r. F.\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eLagertemperatur\u003c\/th\u003e\n\u003ctd\u003e-10 bis +85 °C\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eLagerfeuchte\u003c\/th\u003e\n\u003ctd\u003e0 bis 95 % r. F., nicht kondensierend\u003c\/td\u003e\n\u003c\/tr\u003e      \u003c\/tbody\u003e    \u003c\/table\u003e  \u003c\/div\u003e  \u003cdiv\u003e    \u003ch3\u003eDTS-System für Ihr Projekt auslegen\u003c\/h3\u003e    \u003cp\u003eFür eine belastbare Systemauswahl müssen Reichweite, Anzahl und Führung der Messkanäle, Sensorkabel, Temperaturbereich, Alarmzonen sowie die Einbindung in Brandmelde-, Leit- oder Automatisierungssysteme gemeinsam betrachtet werden.\u003c\/p\u003e    \u003cp\u003e\u003ca href=\"https:\/\/shop.abatec.de\/pages\/kontakt\"\u003eSprechen Sie mit abatec über Ihre DTS-Anwendung und die technische Projektierung.\u003c\/a\u003e\u003c\/p\u003e  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"FOTAS","offers":[{"title":"Default Title","offer_id":67581902848390,"sku":"DTS-CH1-10KM","price":26523.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1111\/8768\/9862\/files\/image_1950_db763743-ab3d-49d5-840f-e1b04a25a202.webp?v=1791369905"},{"product_id":"fotas-dts-ch2-2km-temperatursensor","title":"FOTAS DTS 2 km CH2 Zweikanal-Temperatursensorsystem | DTS-CH2-02KM","description":"\u003cdiv data-product-description=\"fotas-dts-ch2-2km\"\u003e  \u003ch2\u003e\u003cfont color=\"#000000\"\u003eFOTAS DTS 2 km CH2 - verteilte Temperaturmessung für Brandfrüherkennung und Anlagenüberwachung\u003c\/font\u003e\u003c\/h2\u003e  \u003cp\u003eDas \u003cstrong\u003eFOTAS DTS 2 km CH2\u003c\/strong\u003e ist ein faseroptisches System für Distributed Temperature Sensing (DTS). Es erfasst Temperaturverläufe entlang eines Sensorkabels räumlich aufgelöst und eignet sich damit für die kontinuierliche thermische Überwachung ausgedehnter Anlagen und Infrastrukturen.\u003c\/p\u003e  \u003cp\u003eDie angebotene CH2-Ausführung ist für eine Konfiguration mit zwei Messkanälen vorgesehen. Das offizielle FOTAS-Datenblatt führt für die 2-km-Variante Reichweiten von bis zu 2 km je Kanal sowie Gerätevarianten mit einem, zwei oder vier Kanälen auf. Dadurch lassen sich mehrere Überwachungsbereiche von einer zentralen Einheit aus erfassen.\u003c\/p\u003e  \u003ch3\u003eSo funktioniert Distributed Temperature Sensing\u003c\/h3\u003e  \u003cp\u003eDas DTS-Gerät sendet Laserlicht mit 1.550 nm in eine multimodale Glasfaser. Aus dem temperaturabhängigen rückgestreuten Licht ermittelt das System fortlaufend Temperaturwerte entlang der gesamten Messstrecke. Auf diese Weise wird das Sensorkabel zu einem linienförmigen Temperatursensor mit einem Abtastintervall von 1 m.\u003c\/p\u003e  \u003cp\u003eFür die 2-km-Ausführung nennt der Hersteller eine Temperaturauflösung von 0,1 °C bei 10 Sekunden Messzeit und eine Temperaturgenauigkeit von ±1 °C. Ein Faserbruch wird automatisch erkannt und mit einer Genauigkeit von weniger als ±5 m lokalisiert.\u003c\/p\u003e  \u003cfont color=\"#222222\"\u003e\u003cspan\u003e\u003cimg src=\"https:\/\/eu.myikas.com\/images\/2dc48198-b7a0-4f63-8807-7824d0c41208\/1f60cf10-eb62-49ef-8ea5-82f396916520\/720\/1.webp\" alt=\"FOTAS DTS CH2 Zweikanal-System für verteilte Temperaturmessung bis 2 km je Kanal\" title=\"FOTAS DTS-CH2-02KM Distributed Temperature Sensing\" loading=\"lazy\"\u003e\u003c\/span\u003e\u003c\/font\u003e  \u003ch3\u003eIhre Vorteile auf einen Blick\u003c\/h3\u003e  \u003cul\u003e    \u003cli\u003e\n\u003cstrong\u003eVerteilte Messung:\u003c\/strong\u003e Temperaturdaten entlang der gesamten Glasfaser statt nur an einzelnen Messpunkten\u003c\/li\u003e    \u003cli\u003e\n\u003cstrong\u003eGroße Reichweite:\u003c\/strong\u003e bis zu 2 km je Kanal\u003c\/li\u003e    \u003cli\u003e\n\u003cstrong\u003eZweikanal-Konfiguration:\u003c\/strong\u003e mehrere Messstrecken oder Anlagenbereiche zentral überwachen\u003c\/li\u003e    \u003cli\u003e\n\u003cstrong\u003eGenaue Lokalisierung:\u003c\/strong\u003e 1 m Abtastintervall und automatische Faserbruchmeldung\u003c\/li\u003e    \u003cli\u003e\n\u003cstrong\u003eSystemintegration:\u003c\/strong\u003e Modbus TCP, Modbus RTU, Relais, Ethernet und serielle Schnittstellen\u003c\/li\u003e    \u003cli\u003e\n\u003cstrong\u003eFlexible Alarmierung:\u003c\/strong\u003e Grenzwert-, Minimum-, Temperaturanstiegs- und Abweichungsalarme\u003c\/li\u003e  \u003c\/ul\u003e  \u003ch3\u003eTypische Einsatzbereiche\u003c\/h3\u003e  \u003cul\u003e    \u003cli\u003eLineare Brandfrüherkennung in Straßen-, Bahn- und Versorgungstunneln\u003c\/li\u003e    \u003cli\u003eThermische Überwachung von Energie- und Leistungskabeln\u003c\/li\u003e    \u003cli\u003eTemperaturüberwachung in Industrieanlagen, Lagern und Rechenzentren\u003c\/li\u003e    \u003cli\u003eErkennung thermischer Auffälligkeiten entlang von Rohrleitungen und technischen Trassen\u003c\/li\u003e    \u003cli\u003eZonenbasierte Überwachung komplexer Infrastrukturprojekte\u003c\/li\u003e  \u003c\/ul\u003e  \u003ch3\u003eTechnische Highlights\u003c\/h3\u003e  \u003cdiv\u003e    \u003ctable\u003e      \u003ctbody\u003e        \u003ctr\u003e\n\u003cth\u003eArtikelnummer \/ Ausführung\u003c\/th\u003e\n\u003ctd\u003eDTS-CH2-02KM \/ CH2\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eSensortechnologie\u003c\/th\u003e\n\u003ctd\u003eDistributed Temperature Sensing (DTS)\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eReichweite\u003c\/th\u003e\n\u003ctd\u003eBis zu 2 km je Kanal\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eKanaloptionen laut Hersteller\u003c\/th\u003e\n\u003ctd\u003e1 \/ 2 \/ 4; Shopausführung CH2\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eAbtastintervall\u003c\/th\u003e\n\u003ctd\u003e1 m\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eTemperaturauflösung bei 2 km\u003c\/th\u003e\n\u003ctd\u003e0,1 °C bei 10 s\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eTemperaturgenauigkeit\u003c\/th\u003e\n\u003ctd\u003e±1 °C\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eMesszeit\u003c\/th\u003e\n\u003ctd\u003eTypisch ca. 5 s bei linearen Wärmeanwendungen (Herstellerangabe mit Bezug auf EN 54-22)\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eFaserbruchalarm\u003c\/th\u003e\n\u003ctd\u003eAutomatische Erkennung, Ortungsgenauigkeit \u0026lt; ±5 m\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eMessbarer Temperaturbereich\u003c\/th\u003e\n\u003ctd\u003e-220 bis +800 °C, abhängig vom eingesetzten faseroptischen Sensorkabel\u003c\/td\u003e\n\u003c\/tr\u003e      \u003c\/tbody\u003e    \u003c\/table\u003e  \u003c\/div\u003e  \u003ch3\u003eOptische, elektrische und mechanische Daten\u003c\/h3\u003e  \u003cdiv\u003e    \u003ctable\u003e      \u003ctbody\u003e        \u003ctr\u003e\n\u003cth\u003eLaserwellenlänge\u003c\/th\u003e\n\u003ctd\u003e1.550 nm\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eOptisches Budget\u003c\/th\u003e\n\u003ctd\u003e10 dB\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eAnschluss \/ Fasertyp\u003c\/th\u003e\n\u003ctd\u003eE2000 \/ Multimode 62,5\/125\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eLasersicherheitsklasse\u003c\/th\u003e\n\u003ctd\u003eKlasse 1\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eVersorgung \/ Leistungsaufnahme\u003c\/th\u003e\n\u003ctd\u003e24 V DC \/ maximal 85 W\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eBauform \/ Schutzart\u003c\/th\u003e\n\u003ctd\u003e3 HE \/ IP40\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eAbmessungen (B × H × T)\u003c\/th\u003e\n\u003ctd\u003e485 × 133 × 509 mm\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eNettogewicht\u003c\/th\u003e\n\u003ctd\u003e10 kg\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eGehäuse\u003c\/th\u003e\n\u003ctd\u003eLackierter verzinkter Stahl, mattschwarz\u003c\/td\u003e\n\u003c\/tr\u003e      \u003c\/tbody\u003e    \u003c\/table\u003e  \u003c\/div\u003e  \u003ch3\u003eSchnittstellen, Alarmierung und Software\u003c\/h3\u003e  \u003cul\u003e    \u003cli\u003e48 NO\/NC-Relaiskontakte\u003c\/li\u003e    \u003cli\u003eModbus TCP und Modbus RTU\u003c\/li\u003e    \u003cli\u003e1 × RJ45 mit 100 Mbit\/s\u003c\/li\u003e    \u003cli\u003e1 × RS-485, 1 × RS-232 und 1 × USB\u003c\/li\u003e    \u003cli\u003e7-Zoll-Touchscreen mit 1.024 × 600 Pixeln\u003c\/li\u003e    \u003cli\u003eInterner Speicher für mehr als 500.000 Messungen bei 10 km (Hersteller-Benchmark)\u003c\/li\u003e    \u003cli\u003eFOTAS Web mit bis zu 1.000 Zonen und Alarmen für Maximum, Minimum, Anstiegsrate und Abweichung\u003c\/li\u003e  \u003c\/ul\u003e  \u003ch3\u003eUmgebungsbedingungen\u003c\/h3\u003e  \u003cdiv\u003e    \u003ctable\u003e      \u003ctbody\u003e        \u003ctr\u003e\n\u003cth\u003eBetriebstemperatur\u003c\/th\u003e\n\u003ctd\u003e-10 bis +55 °C\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eBetriebsfeuchte\u003c\/th\u003e\n\u003ctd\u003e0 bis 95 % r. F.\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eLagertemperatur\u003c\/th\u003e\n\u003ctd\u003e-10 bis +85 °C\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eLagerfeuchte\u003c\/th\u003e\n\u003ctd\u003e0 bis 95 % r. F., nicht kondensierend\u003c\/td\u003e\n\u003c\/tr\u003e      \u003c\/tbody\u003e    \u003c\/table\u003e  \u003c\/div\u003e  \u003cdiv\u003e    \u003ch3\u003eDTS-System für Ihr Projekt auslegen\u003c\/h3\u003e    \u003cp\u003eFür eine belastbare Systemauswahl müssen Reichweite, Anzahl und Führung der Messkanäle, Sensorkabel, Temperaturbereich, Alarmzonen sowie die Einbindung in Brandmelde-, Leit- oder Automatisierungssysteme gemeinsam betrachtet werden.\u003c\/p\u003e    \u003cp\u003e\u003ca href=\"https:\/\/shop.abatec.de\/pages\/kontakt\"\u003eSprechen Sie mit abatec über Ihre DTS-Anwendung und die technische Projektierung.\u003c\/a\u003e\u003c\/p\u003e  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"FOTAS","offers":[{"title":"Default Title","offer_id":67581902913926,"sku":"DTS-CH2-02KM","price":23547.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1111\/8768\/9862\/files\/image_1950_7edab586-960a-483f-b99b-40c49e2f1a8e.webp?v=1791369906"},{"product_id":"fotas-dts-ch2-4km-temperatursensor","title":"FOTAS DTS 4 km CH2 Zweikanal-Temperatursensorsystem | DTS-CH2-04KM","description":"\u003cdiv data-product-description=\"fotas-dts-ch2-4km\"\u003e  \u003ch2\u003e\u003cfont color=\"#000000\"\u003eFOTAS DTS 4 km CH2 - verteilte Temperaturmessung für Brandfrüherkennung und Anlagenüberwachung\u003c\/font\u003e\u003c\/h2\u003e  \u003cp\u003eDas \u003cstrong\u003eFOTAS DTS 4 km CH2\u003c\/strong\u003e ist ein faseroptisches System für Distributed Temperature Sensing (DTS). Es erfasst Temperaturverläufe entlang eines Sensorkabels räumlich aufgelöst und eignet sich damit für die kontinuierliche thermische Überwachung ausgedehnter Anlagen und Infrastrukturen.\u003c\/p\u003e  \u003cp\u003eDie angebotene CH2-Ausführung ist für eine Konfiguration mit zwei Messkanälen vorgesehen. Das offizielle FOTAS-Datenblatt führt für die 4-km-Variante Reichweiten von bis zu 4 km je Kanal sowie Gerätevarianten mit einem, zwei oder vier Kanälen auf. Dadurch lassen sich mehrere Überwachungsbereiche von einer zentralen Einheit aus erfassen.\u003c\/p\u003e  \u003ch3\u003eSo funktioniert Distributed Temperature Sensing\u003c\/h3\u003e  \u003cp\u003eDas DTS-Gerät sendet Laserlicht mit 1.550 nm in eine multimodale Glasfaser. Aus dem temperaturabhängigen rückgestreuten Licht ermittelt das System fortlaufend Temperaturwerte entlang der gesamten Messstrecke. Auf diese Weise wird das Sensorkabel zu einem linienförmigen Temperatursensor mit einem Abtastintervall von 1 m.\u003c\/p\u003e  \u003cp\u003eFür die 4-km-Ausführung nennt der Hersteller eine Temperaturauflösung von 0,1 °C bei 10 Sekunden Messzeit und eine Temperaturgenauigkeit von ±1 °C. Ein Faserbruch wird automatisch erkannt und mit einer Genauigkeit von weniger als ±5 m lokalisiert.\u003c\/p\u003e  \u003cfont color=\"#222222\"\u003e\u003cspan\u003e\u003cimg src=\"https:\/\/eu.myikas.com\/images\/2dc48198-b7a0-4f63-8807-7824d0c41208\/3b5e0628-4677-49d2-9d50-a132e1d3fbbd\/720\/1.webp\" alt=\"FOTAS DTS CH2 Zweikanal-System für verteilte Temperaturmessung bis 4 km je Kanal\" title=\"FOTAS DTS-CH2-04KM Distributed Temperature Sensing\" loading=\"lazy\"\u003e\u003c\/span\u003e\u003c\/font\u003e  \u003ch3\u003eIhre Vorteile auf einen Blick\u003c\/h3\u003e  \u003cul\u003e    \u003cli\u003e\n\u003cstrong\u003eVerteilte Messung:\u003c\/strong\u003e Temperaturdaten entlang der gesamten Glasfaser statt nur an einzelnen Messpunkten\u003c\/li\u003e    \u003cli\u003e\n\u003cstrong\u003eGroße Reichweite:\u003c\/strong\u003e bis zu 4 km je Kanal\u003c\/li\u003e    \u003cli\u003e\n\u003cstrong\u003eZweikanal-Konfiguration:\u003c\/strong\u003e mehrere Messstrecken oder Anlagenbereiche zentral überwachen\u003c\/li\u003e    \u003cli\u003e\n\u003cstrong\u003eGenaue Lokalisierung:\u003c\/strong\u003e 1 m Abtastintervall und automatische Faserbruchmeldung\u003c\/li\u003e    \u003cli\u003e\n\u003cstrong\u003eSystemintegration:\u003c\/strong\u003e Modbus TCP, Modbus RTU, Relais, Ethernet und serielle Schnittstellen\u003c\/li\u003e    \u003cli\u003e\n\u003cstrong\u003eFlexible Alarmierung:\u003c\/strong\u003e Grenzwert-, Minimum-, Temperaturanstiegs- und Abweichungsalarme\u003c\/li\u003e  \u003c\/ul\u003e  \u003ch3\u003eTypische Einsatzbereiche\u003c\/h3\u003e  \u003cul\u003e    \u003cli\u003eLineare Brandfrüherkennung in Straßen-, Bahn- und Versorgungstunneln\u003c\/li\u003e    \u003cli\u003eThermische Überwachung von Energie- und Leistungskabeln\u003c\/li\u003e    \u003cli\u003eTemperaturüberwachung in Industrieanlagen, Lagern und Rechenzentren\u003c\/li\u003e    \u003cli\u003eErkennung thermischer Auffälligkeiten entlang von Rohrleitungen und technischen Trassen\u003c\/li\u003e    \u003cli\u003eZonenbasierte Überwachung komplexer Infrastrukturprojekte\u003c\/li\u003e  \u003c\/ul\u003e  \u003ch3\u003eTechnische Highlights\u003c\/h3\u003e  \u003cdiv\u003e    \u003ctable\u003e      \u003ctbody\u003e        \u003ctr\u003e\n\u003cth\u003eArtikelnummer \/ Ausführung\u003c\/th\u003e\n\u003ctd\u003eDTS-CH2-04KM \/ CH2\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eSensortechnologie\u003c\/th\u003e\n\u003ctd\u003eDistributed Temperature Sensing (DTS)\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eReichweite\u003c\/th\u003e\n\u003ctd\u003eBis zu 4 km je Kanal\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eKanaloptionen laut Hersteller\u003c\/th\u003e\n\u003ctd\u003e1 \/ 2 \/ 4; Shopausführung CH2\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eAbtastintervall\u003c\/th\u003e\n\u003ctd\u003e1 m\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eTemperaturauflösung bei 4 km\u003c\/th\u003e\n\u003ctd\u003e0,1 °C bei 10 s\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eTemperaturgenauigkeit\u003c\/th\u003e\n\u003ctd\u003e±1 °C\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eMesszeit\u003c\/th\u003e\n\u003ctd\u003eTypisch ca. 5 s bei linearen Wärmeanwendungen (Herstellerangabe mit Bezug auf EN 54-22)\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eFaserbruchalarm\u003c\/th\u003e\n\u003ctd\u003eAutomatische Erkennung, Ortungsgenauigkeit \u0026lt; ±5 m\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eMessbarer Temperaturbereich\u003c\/th\u003e\n\u003ctd\u003e-220 bis +800 °C, abhängig vom eingesetzten faseroptischen Sensorkabel\u003c\/td\u003e\n\u003c\/tr\u003e      \u003c\/tbody\u003e    \u003c\/table\u003e  \u003c\/div\u003e  \u003ch3\u003eOptische, elektrische und mechanische Daten\u003c\/h3\u003e  \u003cdiv\u003e    \u003ctable\u003e      \u003ctbody\u003e        \u003ctr\u003e\n\u003cth\u003eLaserwellenlänge\u003c\/th\u003e\n\u003ctd\u003e1.550 nm\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eOptisches Budget\u003c\/th\u003e\n\u003ctd\u003e10 dB\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eAnschluss \/ Fasertyp\u003c\/th\u003e\n\u003ctd\u003eE2000 \/ Multimode 62,5\/125\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eLasersicherheitsklasse\u003c\/th\u003e\n\u003ctd\u003eKlasse 1\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eVersorgung \/ Leistungsaufnahme\u003c\/th\u003e\n\u003ctd\u003e24 V DC \/ maximal 85 W\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eBauform \/ Schutzart\u003c\/th\u003e\n\u003ctd\u003e3 HE \/ IP40\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eAbmessungen (B × H × T)\u003c\/th\u003e\n\u003ctd\u003e485 × 133 × 509 mm\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eNettogewicht\u003c\/th\u003e\n\u003ctd\u003e10 kg\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eGehäuse\u003c\/th\u003e\n\u003ctd\u003eLackierter verzinkter Stahl, mattschwarz\u003c\/td\u003e\n\u003c\/tr\u003e      \u003c\/tbody\u003e    \u003c\/table\u003e  \u003c\/div\u003e  \u003ch3\u003eSchnittstellen, Alarmierung und Software\u003c\/h3\u003e  \u003cul\u003e    \u003cli\u003e48 NO\/NC-Relaiskontakte\u003c\/li\u003e    \u003cli\u003eModbus TCP und Modbus RTU\u003c\/li\u003e    \u003cli\u003e1 × RJ45 mit 100 Mbit\/s\u003c\/li\u003e    \u003cli\u003e1 × RS-485, 1 × RS-232 und 1 × USB\u003c\/li\u003e    \u003cli\u003e7-Zoll-Touchscreen mit 1.024 × 600 Pixeln\u003c\/li\u003e    \u003cli\u003eInterner Speicher für mehr als 500.000 Messungen bei 10 km (Hersteller-Benchmark)\u003c\/li\u003e    \u003cli\u003eFOTAS Web mit bis zu 1.000 Zonen und Alarmen für Maximum, Minimum, Anstiegsrate und Abweichung\u003c\/li\u003e  \u003c\/ul\u003e  \u003ch3\u003eUmgebungsbedingungen\u003c\/h3\u003e  \u003cdiv\u003e    \u003ctable\u003e      \u003ctbody\u003e        \u003ctr\u003e\n\u003cth\u003eBetriebstemperatur\u003c\/th\u003e\n\u003ctd\u003e-10 bis +55 °C\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eBetriebsfeuchte\u003c\/th\u003e\n\u003ctd\u003e0 bis 95 % r. F.\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eLagertemperatur\u003c\/th\u003e\n\u003ctd\u003e-10 bis +85 °C\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eLagerfeuchte\u003c\/th\u003e\n\u003ctd\u003e0 bis 95 % r. F., nicht kondensierend\u003c\/td\u003e\n\u003c\/tr\u003e      \u003c\/tbody\u003e    \u003c\/table\u003e  \u003c\/div\u003e  \u003cdiv\u003e    \u003ch3\u003eDTS-System für Ihr Projekt auslegen\u003c\/h3\u003e    \u003cp\u003eFür eine belastbare Systemauswahl müssen Reichweite, Anzahl und Führung der Messkanäle, Sensorkabel, Temperaturbereich, Alarmzonen sowie die Einbindung in Brandmelde-, Leit- oder Automatisierungssysteme gemeinsam betrachtet werden.\u003c\/p\u003e    \u003cp\u003e\u003ca href=\"https:\/\/shop.abatec.de\/pages\/kontakt\"\u003eSprechen Sie mit abatec über Ihre DTS-Anwendung und die technische Projektierung.\u003c\/a\u003e\u003c\/p\u003e  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"FOTAS","offers":[{"title":"Default Title","offer_id":67581902979462,"sku":"DTS-CH2-04KM","price":25100.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1111\/8768\/9862\/files\/image_1950_ee4ac908-2846-4fb5-81af-f1c57b334c6b.webp?v=1791369906"},{"product_id":"fotas-dts-ch2-8km-temperatursensor","title":"FOTAS DTS 8 km CH2 Zweikanal-Temperatursensorsystem | DTS-CH2-08KM","description":"\u003cdiv data-product-description=\"fotas-dts-ch2-8km\"\u003e  \u003ch2\u003e\u003cfont color=\"#000000\"\u003eFOTAS DTS 8 km CH2 - verteilte Temperaturmessung für Brandfrüherkennung und Anlagenüberwachung\u003c\/font\u003e\u003c\/h2\u003e  \u003cp\u003eDas \u003cstrong\u003eFOTAS DTS 8 km CH2\u003c\/strong\u003e ist ein faseroptisches System für Distributed Temperature Sensing (DTS). Es erfasst Temperaturverläufe entlang eines Sensorkabels räumlich aufgelöst und eignet sich damit für die kontinuierliche thermische Überwachung ausgedehnter Anlagen und Infrastrukturen.\u003c\/p\u003e  \u003cp\u003eDie angebotene CH2-Ausführung ist für eine Konfiguration mit zwei Messkanälen vorgesehen. Das offizielle FOTAS-Datenblatt führt für die 8-km-Variante Reichweiten von bis zu 8 km je Kanal sowie Gerätevarianten mit einem, zwei oder vier Kanälen auf. Dadurch lassen sich mehrere Überwachungsbereiche von einer zentralen Einheit aus erfassen.\u003c\/p\u003e  \u003ch3\u003eSo funktioniert Distributed Temperature Sensing\u003c\/h3\u003e  \u003cp\u003eDas DTS-Gerät sendet Laserlicht mit 1.550 nm in eine multimodale Glasfaser. Aus dem temperaturabhängigen rückgestreuten Licht ermittelt das System fortlaufend Temperaturwerte entlang der gesamten Messstrecke. Auf diese Weise wird das Sensorkabel zu einem linienförmigen Temperatursensor mit einem Abtastintervall von 1 m.\u003c\/p\u003e  \u003cp\u003eFür die 8-km-Ausführung nennt der Hersteller eine Temperaturauflösung von 0,3 °C bei 10 Sekunden Messzeit und eine Temperaturgenauigkeit von ±1 °C. Ein Faserbruch wird automatisch erkannt und mit einer Genauigkeit von weniger als ±5 m lokalisiert.\u003c\/p\u003e  \u003cfont color=\"#222222\"\u003e\u003cspan\u003e\u003cimg src=\"https:\/\/eu.myikas.com\/images\/2dc48198-b7a0-4f63-8807-7824d0c41208\/64ea5a12-1550-46d2-9f23-8402f51976ed\/720\/1.webp\" alt=\"FOTAS DTS CH2 Zweikanal-System für verteilte Temperaturmessung bis 8 km je Kanal\" title=\"FOTAS DTS-CH2-08KM Distributed Temperature Sensing\" loading=\"lazy\"\u003e\u003c\/span\u003e\u003c\/font\u003e  \u003ch3\u003eIhre Vorteile auf einen Blick\u003c\/h3\u003e  \u003cul\u003e    \u003cli\u003e\n\u003cstrong\u003eVerteilte Messung:\u003c\/strong\u003e Temperaturdaten entlang der gesamten Glasfaser statt nur an einzelnen Messpunkten\u003c\/li\u003e    \u003cli\u003e\n\u003cstrong\u003eGroße Reichweite:\u003c\/strong\u003e bis zu 8 km je Kanal\u003c\/li\u003e    \u003cli\u003e\n\u003cstrong\u003eZweikanal-Konfiguration:\u003c\/strong\u003e mehrere Messstrecken oder Anlagenbereiche zentral überwachen\u003c\/li\u003e    \u003cli\u003e\n\u003cstrong\u003eGenaue Lokalisierung:\u003c\/strong\u003e 1 m Abtastintervall und automatische Faserbruchmeldung\u003c\/li\u003e    \u003cli\u003e\n\u003cstrong\u003eSystemintegration:\u003c\/strong\u003e Modbus TCP, Modbus RTU, Relais, Ethernet und serielle Schnittstellen\u003c\/li\u003e    \u003cli\u003e\n\u003cstrong\u003eFlexible Alarmierung:\u003c\/strong\u003e Grenzwert-, Minimum-, Temperaturanstiegs- und Abweichungsalarme\u003c\/li\u003e  \u003c\/ul\u003e  \u003ch3\u003eTypische Einsatzbereiche\u003c\/h3\u003e  \u003cul\u003e    \u003cli\u003eLineare Brandfrüherkennung in Straßen-, Bahn- und Versorgungstunneln\u003c\/li\u003e    \u003cli\u003eThermische Überwachung von Energie- und Leistungskabeln\u003c\/li\u003e    \u003cli\u003eTemperaturüberwachung in Industrieanlagen, Lagern und Rechenzentren\u003c\/li\u003e    \u003cli\u003eErkennung thermischer Auffälligkeiten entlang von Rohrleitungen und technischen Trassen\u003c\/li\u003e    \u003cli\u003eZonenbasierte Überwachung komplexer Infrastrukturprojekte\u003c\/li\u003e  \u003c\/ul\u003e  \u003ch3\u003eTechnische Highlights\u003c\/h3\u003e  \u003cdiv\u003e    \u003ctable\u003e      \u003ctbody\u003e        \u003ctr\u003e\n\u003cth\u003eArtikelnummer \/ Ausführung\u003c\/th\u003e\n\u003ctd\u003eDTS-CH2-08KM \/ CH2\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eSensortechnologie\u003c\/th\u003e\n\u003ctd\u003eDistributed Temperature Sensing (DTS)\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eReichweite\u003c\/th\u003e\n\u003ctd\u003eBis zu 8 km je Kanal\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eKanaloptionen laut Hersteller\u003c\/th\u003e\n\u003ctd\u003e1 \/ 2 \/ 4; Shopausführung CH2\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eAbtastintervall\u003c\/th\u003e\n\u003ctd\u003e1 m\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eTemperaturauflösung bei 8 km\u003c\/th\u003e\n\u003ctd\u003e0,3 °C bei 10 s\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eTemperaturgenauigkeit\u003c\/th\u003e\n\u003ctd\u003e±1 °C\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eMesszeit\u003c\/th\u003e\n\u003ctd\u003eTypisch ca. 5 s bei linearen Wärmeanwendungen (Herstellerangabe mit Bezug auf EN 54-22)\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eFaserbruchalarm\u003c\/th\u003e\n\u003ctd\u003eAutomatische Erkennung, Ortungsgenauigkeit \u0026lt; ±5 m\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eMessbarer Temperaturbereich\u003c\/th\u003e\n\u003ctd\u003e-220 bis +800 °C, abhängig vom eingesetzten faseroptischen Sensorkabel\u003c\/td\u003e\n\u003c\/tr\u003e      \u003c\/tbody\u003e    \u003c\/table\u003e  \u003c\/div\u003e  \u003ch3\u003eOptische, elektrische und mechanische Daten\u003c\/h3\u003e  \u003cdiv\u003e    \u003ctable\u003e      \u003ctbody\u003e        \u003ctr\u003e\n\u003cth\u003eLaserwellenlänge\u003c\/th\u003e\n\u003ctd\u003e1.550 nm\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eOptisches Budget\u003c\/th\u003e\n\u003ctd\u003e10 dB\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eAnschluss \/ Fasertyp\u003c\/th\u003e\n\u003ctd\u003eE2000 \/ Multimode 62,5\/125\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eLasersicherheitsklasse\u003c\/th\u003e\n\u003ctd\u003eKlasse 1\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eVersorgung \/ Leistungsaufnahme\u003c\/th\u003e\n\u003ctd\u003e24 V DC \/ maximal 85 W\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eBauform \/ Schutzart\u003c\/th\u003e\n\u003ctd\u003e3 HE \/ IP40\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eAbmessungen (B × H × T)\u003c\/th\u003e\n\u003ctd\u003e485 × 133 × 509 mm\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eNettogewicht\u003c\/th\u003e\n\u003ctd\u003e10 kg\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eGehäuse\u003c\/th\u003e\n\u003ctd\u003eLackierter verzinkter Stahl, mattschwarz\u003c\/td\u003e\n\u003c\/tr\u003e      \u003c\/tbody\u003e    \u003c\/table\u003e  \u003c\/div\u003e  \u003ch3\u003eSchnittstellen, Alarmierung und Software\u003c\/h3\u003e  \u003cul\u003e    \u003cli\u003e48 NO\/NC-Relaiskontakte\u003c\/li\u003e    \u003cli\u003eModbus TCP und Modbus RTU\u003c\/li\u003e    \u003cli\u003e1 × RJ45 mit 100 Mbit\/s\u003c\/li\u003e    \u003cli\u003e1 × RS-485, 1 × RS-232 und 1 × USB\u003c\/li\u003e    \u003cli\u003e7-Zoll-Touchscreen mit 1.024 × 600 Pixeln\u003c\/li\u003e    \u003cli\u003eInterner Speicher für mehr als 500.000 Messungen bei 10 km (Hersteller-Benchmark)\u003c\/li\u003e    \u003cli\u003eFOTAS Web mit bis zu 1.000 Zonen und Alarmen für Maximum, Minimum, Anstiegsrate und Abweichung\u003c\/li\u003e  \u003c\/ul\u003e  \u003ch3\u003eUmgebungsbedingungen\u003c\/h3\u003e  \u003cdiv\u003e    \u003ctable\u003e      \u003ctbody\u003e        \u003ctr\u003e\n\u003cth\u003eBetriebstemperatur\u003c\/th\u003e\n\u003ctd\u003e-10 bis +55 °C\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eBetriebsfeuchte\u003c\/th\u003e\n\u003ctd\u003e0 bis 95 % r. F.\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eLagertemperatur\u003c\/th\u003e\n\u003ctd\u003e-10 bis +85 °C\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eLagerfeuchte\u003c\/th\u003e\n\u003ctd\u003e0 bis 95 % r. F., nicht kondensierend\u003c\/td\u003e\n\u003c\/tr\u003e      \u003c\/tbody\u003e    \u003c\/table\u003e  \u003c\/div\u003e  \u003cdiv\u003e    \u003ch3\u003eDTS-System für Ihr Projekt auslegen\u003c\/h3\u003e    \u003cp\u003eFür eine belastbare Systemauswahl müssen Reichweite, Anzahl und Führung der Messkanäle, Sensorkabel, Temperaturbereich, Alarmzonen sowie die Einbindung in Brandmelde-, Leit- oder Automatisierungssysteme gemeinsam betrachtet werden.\u003c\/p\u003e    \u003cp\u003e\u003ca href=\"https:\/\/shop.abatec.de\/pages\/kontakt\"\u003eSprechen Sie mit abatec über Ihre DTS-Anwendung und die technische Projektierung.\u003c\/a\u003e\u003c\/p\u003e  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"FOTAS","offers":[{"title":"Default Title","offer_id":67581903044998,"sku":"DTS-CH2-08KM","price":26910.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1111\/8768\/9862\/files\/image_1950_fbb22275-5e48-4e99-928a-67202851df6d.webp?v=1791369907"},{"product_id":"fotas-dts-ch2-10km-temperatursensor","title":"FOTAS DTS 10 km CH2 Zweikanal-Temperatursensorsystem | DTS-CH2-10KM","description":"\u003cdiv data-product-description=\"fotas-dts-ch2-10km\"\u003e  \u003ch2\u003e\u003cfont color=\"#000000\"\u003eFOTAS DTS 10 km CH2 - verteilte Temperaturmessung für Brandfrüherkennung und Anlagenüberwachung\u003c\/font\u003e\u003c\/h2\u003e  \u003cp\u003eDas \u003cstrong\u003eFOTAS DTS 10 km CH2\u003c\/strong\u003e ist ein faseroptisches System für Distributed Temperature Sensing (DTS). Es erfasst Temperaturverläufe entlang eines Sensorkabels räumlich aufgelöst und eignet sich damit für die kontinuierliche thermische Überwachung ausgedehnter Anlagen und Infrastrukturen.\u003c\/p\u003e  \u003cp\u003eDie angebotene CH2-Ausführung ist für eine Konfiguration mit zwei Messkanälen vorgesehen. Das offizielle FOTAS-Datenblatt führt für die 10-km-Variante Reichweiten von bis zu 10 km je Kanal sowie Gerätevarianten mit einem, zwei oder vier Kanälen auf. Dadurch lassen sich mehrere Überwachungsbereiche von einer zentralen Einheit aus erfassen.\u003c\/p\u003e  \u003ch3\u003eSo funktioniert Distributed Temperature Sensing\u003c\/h3\u003e  \u003cp\u003eDas DTS-Gerät sendet Laserlicht mit 1.550 nm in eine multimodale Glasfaser. Aus dem temperaturabhängigen rückgestreuten Licht ermittelt das System fortlaufend Temperaturwerte entlang der gesamten Messstrecke. Auf diese Weise wird das Sensorkabel zu einem linienförmigen Temperatursensor mit einem Abtastintervall von 1 m.\u003c\/p\u003e  \u003cp\u003eFür die 10-km-Ausführung nennt der Hersteller eine Temperaturauflösung von 0,3 °C bei 10 Sekunden Messzeit und eine Temperaturgenauigkeit von ±1 °C. Ein Faserbruch wird automatisch erkannt und mit einer Genauigkeit von weniger als ±5 m lokalisiert.\u003c\/p\u003e  \u003cfont color=\"#222222\"\u003e\u003cspan\u003e\u003cimg src=\"https:\/\/eu.myikas.com\/images\/2dc48198-b7a0-4f63-8807-7824d0c41208\/f045f040-8cbb-42c1-94ce-41e1e0972f33\/720\/1.webp\" alt=\"FOTAS DTS CH2 Zweikanal-System für verteilte Temperaturmessung bis 10 km je Kanal\" title=\"FOTAS DTS-CH2-10KM Distributed Temperature Sensing\" loading=\"lazy\"\u003e\u003c\/span\u003e\u003c\/font\u003e  \u003ch3\u003eIhre Vorteile auf einen Blick\u003c\/h3\u003e  \u003cul\u003e    \u003cli\u003e\n\u003cstrong\u003eVerteilte Messung:\u003c\/strong\u003e Temperaturdaten entlang der gesamten Glasfaser statt nur an einzelnen Messpunkten\u003c\/li\u003e    \u003cli\u003e\n\u003cstrong\u003eGroße Reichweite:\u003c\/strong\u003e bis zu 10 km je Kanal\u003c\/li\u003e    \u003cli\u003e\n\u003cstrong\u003eZweikanal-Konfiguration:\u003c\/strong\u003e mehrere Messstrecken oder Anlagenbereiche zentral überwachen\u003c\/li\u003e    \u003cli\u003e\n\u003cstrong\u003eGenaue Lokalisierung:\u003c\/strong\u003e 1 m Abtastintervall und automatische Faserbruchmeldung\u003c\/li\u003e    \u003cli\u003e\n\u003cstrong\u003eSystemintegration:\u003c\/strong\u003e Modbus TCP, Modbus RTU, Relais, Ethernet und serielle Schnittstellen\u003c\/li\u003e    \u003cli\u003e\n\u003cstrong\u003eFlexible Alarmierung:\u003c\/strong\u003e Grenzwert-, Minimum-, Temperaturanstiegs- und Abweichungsalarme\u003c\/li\u003e  \u003c\/ul\u003e  \u003ch3\u003eTypische Einsatzbereiche\u003c\/h3\u003e  \u003cul\u003e    \u003cli\u003eLineare Brandfrüherkennung in Straßen-, Bahn- und Versorgungstunneln\u003c\/li\u003e    \u003cli\u003eThermische Überwachung von Energie- und Leistungskabeln\u003c\/li\u003e    \u003cli\u003eTemperaturüberwachung in Industrieanlagen, Lagern und Rechenzentren\u003c\/li\u003e    \u003cli\u003eErkennung thermischer Auffälligkeiten entlang von Rohrleitungen und technischen Trassen\u003c\/li\u003e    \u003cli\u003eZonenbasierte Überwachung komplexer Infrastrukturprojekte\u003c\/li\u003e  \u003c\/ul\u003e  \u003ch3\u003eTechnische Highlights\u003c\/h3\u003e  \u003cdiv\u003e    \u003ctable\u003e      \u003ctbody\u003e        \u003ctr\u003e\n\u003cth\u003eArtikelnummer \/ Ausführung\u003c\/th\u003e\n\u003ctd\u003eDTS-CH2-10KM \/ CH2\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eSensortechnologie\u003c\/th\u003e\n\u003ctd\u003eDistributed Temperature Sensing (DTS)\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eReichweite\u003c\/th\u003e\n\u003ctd\u003eBis zu 10 km je Kanal\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eKanaloptionen laut Hersteller\u003c\/th\u003e\n\u003ctd\u003e1 \/ 2 \/ 4; Shopausführung CH2\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eAbtastintervall\u003c\/th\u003e\n\u003ctd\u003e1 m\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eTemperaturauflösung bei 10 km\u003c\/th\u003e\n\u003ctd\u003e0,3 °C bei 10 s\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eTemperaturgenauigkeit\u003c\/th\u003e\n\u003ctd\u003e±1 °C\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eMesszeit\u003c\/th\u003e\n\u003ctd\u003eTypisch ca. 5 s bei linearen Wärmeanwendungen (Herstellerangabe mit Bezug auf EN 54-22)\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eFaserbruchalarm\u003c\/th\u003e\n\u003ctd\u003eAutomatische Erkennung, Ortungsgenauigkeit \u0026lt; ±5 m\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eMessbarer Temperaturbereich\u003c\/th\u003e\n\u003ctd\u003e-220 bis +800 °C, abhängig vom eingesetzten faseroptischen Sensorkabel\u003c\/td\u003e\n\u003c\/tr\u003e      \u003c\/tbody\u003e    \u003c\/table\u003e  \u003c\/div\u003e  \u003ch3\u003eOptische, elektrische und mechanische Daten\u003c\/h3\u003e  \u003cdiv\u003e    \u003ctable\u003e      \u003ctbody\u003e        \u003ctr\u003e\n\u003cth\u003eLaserwellenlänge\u003c\/th\u003e\n\u003ctd\u003e1.550 nm\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eOptisches Budget\u003c\/th\u003e\n\u003ctd\u003e10 dB\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eAnschluss \/ Fasertyp\u003c\/th\u003e\n\u003ctd\u003eE2000 \/ Multimode 62,5\/125\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eLasersicherheitsklasse\u003c\/th\u003e\n\u003ctd\u003eKlasse 1\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eVersorgung \/ Leistungsaufnahme\u003c\/th\u003e\n\u003ctd\u003e24 V DC \/ maximal 85 W\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eBauform \/ Schutzart\u003c\/th\u003e\n\u003ctd\u003e3 HE \/ IP40\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eAbmessungen (B × H × T)\u003c\/th\u003e\n\u003ctd\u003e485 × 133 × 509 mm\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eNettogewicht\u003c\/th\u003e\n\u003ctd\u003e10 kg\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eGehäuse\u003c\/th\u003e\n\u003ctd\u003eLackierter verzinkter Stahl, mattschwarz\u003c\/td\u003e\n\u003c\/tr\u003e      \u003c\/tbody\u003e    \u003c\/table\u003e  \u003c\/div\u003e  \u003ch3\u003eSchnittstellen, Alarmierung und Software\u003c\/h3\u003e  \u003cul\u003e    \u003cli\u003e48 NO\/NC-Relaiskontakte\u003c\/li\u003e    \u003cli\u003eModbus TCP und Modbus RTU\u003c\/li\u003e    \u003cli\u003e1 × RJ45 mit 100 Mbit\/s\u003c\/li\u003e    \u003cli\u003e1 × RS-485, 1 × RS-232 und 1 × USB\u003c\/li\u003e    \u003cli\u003e7-Zoll-Touchscreen mit 1.024 × 600 Pixeln\u003c\/li\u003e    \u003cli\u003eInterner Speicher für mehr als 500.000 Messungen bei 10 km\u003c\/li\u003e    \u003cli\u003eFOTAS Web mit bis zu 1.000 Zonen und Alarmen für Maximum, Minimum, Anstiegsrate und Abweichung\u003c\/li\u003e  \u003c\/ul\u003e  \u003ch3\u003eUmgebungsbedingungen\u003c\/h3\u003e  \u003cdiv\u003e    \u003ctable\u003e      \u003ctbody\u003e        \u003ctr\u003e\n\u003cth\u003eBetriebstemperatur\u003c\/th\u003e\n\u003ctd\u003e-10 bis +55 °C\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eBetriebsfeuchte\u003c\/th\u003e\n\u003ctd\u003e0 bis 95 % r. F.\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eLagertemperatur\u003c\/th\u003e\n\u003ctd\u003e-10 bis +85 °C\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eLagerfeuchte\u003c\/th\u003e\n\u003ctd\u003e0 bis 95 % r. F., nicht kondensierend\u003c\/td\u003e\n\u003c\/tr\u003e      \u003c\/tbody\u003e    \u003c\/table\u003e  \u003c\/div\u003e  \u003cdiv\u003e    \u003ch3\u003eDTS-System für Ihr Projekt auslegen\u003c\/h3\u003e    \u003cp\u003eFür eine belastbare Systemauswahl müssen Reichweite, Anzahl und Führung der Messkanäle, Sensorkabel, Temperaturbereich, Alarmzonen sowie die Einbindung in Brandmelde-, Leit- oder Automatisierungssysteme gemeinsam betrachtet werden.\u003c\/p\u003e    \u003cp\u003e\u003ca href=\"https:\/\/shop.abatec.de\/pages\/kontakt\"\u003eSprechen Sie mit abatec über Ihre DTS-Anwendung und die technische Projektierung.\u003c\/a\u003e\u003c\/p\u003e  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"FOTAS","offers":[{"title":"Default Title","offer_id":67581903110534,"sku":"DTS-CH2-10KM","price":28463.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1111\/8768\/9862\/files\/image_1950_239c778f-9048-423e-abc9-c7aba89e1f20.webp?v=1791369908"},{"product_id":"fotas-dts-ch4-2km-temperatursensor","title":"FOTAS DTS 2 km CH4 Vierkanal-Temperatursensorsystem | DTS-CH4-02KM","description":"\u003cdiv data-product-description=\"fotas-dts-ch4-2km\"\u003e  \u003ch2\u003e\u003cfont color=\"#000000\"\u003eFOTAS DTS 2 km CH4 - verteilte Temperaturmessung für Brandfrüherkennung und Anlagenüberwachung\u003c\/font\u003e\u003c\/h2\u003e  \u003cp\u003eDas \u003cstrong\u003eFOTAS DTS 2 km CH4\u003c\/strong\u003e ist ein faseroptisches System für Distributed Temperature Sensing (DTS). Es erfasst Temperaturverläufe entlang eines Sensorkabels räumlich aufgelöst und eignet sich damit für die kontinuierliche thermische Überwachung ausgedehnter Anlagen und Infrastrukturen.\u003c\/p\u003e  \u003cp\u003eDie angebotene CH4-Ausführung ist für eine Konfiguration mit vier Messkanälen vorgesehen. Das offizielle FOTAS-Datenblatt führt für die 2-km-Variante Reichweiten von bis zu 2 km je Kanal sowie Gerätevarianten mit einem, zwei oder vier Kanälen auf. Dadurch lassen sich mehrere Überwachungsbereiche von einer zentralen Einheit aus erfassen.\u003c\/p\u003e  \u003ch3\u003eSo funktioniert Distributed Temperature Sensing\u003c\/h3\u003e  \u003cp\u003eDas DTS-Gerät sendet Laserlicht mit 1.550 nm in eine multimodale Glasfaser. Aus dem temperaturabhängigen rückgestreuten Licht ermittelt das System fortlaufend Temperaturwerte entlang der gesamten Messstrecke. Auf diese Weise wird das Sensorkabel zu einem linienförmigen Temperatursensor mit einem Abtastintervall von 1 m.\u003c\/p\u003e  \u003cp\u003eFür die 2-km-Ausführung nennt der Hersteller eine Temperaturauflösung von 0,1 °C bei 10 Sekunden Messzeit und eine Temperaturgenauigkeit von ±1 °C. Ein Faserbruch wird automatisch erkannt und mit einer Genauigkeit von weniger als ±5 m lokalisiert.\u003c\/p\u003e  \u003cfont color=\"#222222\"\u003e\u003cspan\u003e\u003cimg src=\"https:\/\/eu.myikas.com\/images\/2dc48198-b7a0-4f63-8807-7824d0c41208\/dea1b5be-9d7a-42f1-a75d-344388d9e3e8\/720\/1.webp\" alt=\"FOTAS DTS CH4 Vierkanal-System für verteilte Temperaturmessung bis 2 km je Kanal\" title=\"FOTAS DTS-CH4-02KM Distributed Temperature Sensing\" loading=\"lazy\"\u003e\u003c\/span\u003e\u003c\/font\u003e  \u003ch3\u003eIhre Vorteile auf einen Blick\u003c\/h3\u003e  \u003cul\u003e    \u003cli\u003e\n\u003cstrong\u003eVerteilte Messung:\u003c\/strong\u003e Temperaturdaten entlang der gesamten Glasfaser statt nur an einzelnen Messpunkten\u003c\/li\u003e    \u003cli\u003e\n\u003cstrong\u003eGroße Reichweite:\u003c\/strong\u003e bis zu 2 km je Kanal\u003c\/li\u003e    \u003cli\u003e\n\u003cstrong\u003eVierkanal-Konfiguration:\u003c\/strong\u003e mehrere Messstrecken oder Anlagenbereiche zentral überwachen\u003c\/li\u003e    \u003cli\u003e\n\u003cstrong\u003eGenaue Lokalisierung:\u003c\/strong\u003e 1 m Abtastintervall und automatische Faserbruchmeldung\u003c\/li\u003e    \u003cli\u003e\n\u003cstrong\u003eSystemintegration:\u003c\/strong\u003e Modbus TCP, Modbus RTU, Relais, Ethernet und serielle Schnittstellen\u003c\/li\u003e    \u003cli\u003e\n\u003cstrong\u003eFlexible Alarmierung:\u003c\/strong\u003e Grenzwert-, Minimum-, Temperaturanstiegs- und Abweichungsalarme\u003c\/li\u003e  \u003c\/ul\u003e  \u003ch3\u003eTypische Einsatzbereiche\u003c\/h3\u003e  \u003cul\u003e    \u003cli\u003eLineare Brandfrüherkennung in Straßen-, Bahn- und Versorgungstunneln\u003c\/li\u003e    \u003cli\u003eThermische Überwachung von Energie- und Leistungskabeln\u003c\/li\u003e    \u003cli\u003eTemperaturüberwachung in Industrieanlagen, Lagern und Rechenzentren\u003c\/li\u003e    \u003cli\u003eErkennung thermischer Auffälligkeiten entlang von Rohrleitungen und technischen Trassen\u003c\/li\u003e    \u003cli\u003eZonenbasierte Überwachung komplexer Infrastrukturprojekte\u003c\/li\u003e  \u003c\/ul\u003e  \u003ch3\u003eTechnische Highlights\u003c\/h3\u003e  \u003cdiv\u003e    \u003ctable\u003e      \u003ctbody\u003e        \u003ctr\u003e\n\u003cth\u003eArtikelnummer \/ Ausführung\u003c\/th\u003e\n\u003ctd\u003eDTS-CH4-02KM \/ CH4\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eSensortechnologie\u003c\/th\u003e\n\u003ctd\u003eDistributed Temperature Sensing (DTS)\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eReichweite\u003c\/th\u003e\n\u003ctd\u003eBis zu 2 km je Kanal\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eKanaloptionen laut Hersteller\u003c\/th\u003e\n\u003ctd\u003e1 \/ 2 \/ 4; Shopausführung CH4\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eAbtastintervall\u003c\/th\u003e\n\u003ctd\u003e1 m\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eTemperaturauflösung bei 2 km\u003c\/th\u003e\n\u003ctd\u003e0,1 °C bei 10 s\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eTemperaturgenauigkeit\u003c\/th\u003e\n\u003ctd\u003e±1 °C\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eMesszeit\u003c\/th\u003e\n\u003ctd\u003eTypisch ca. 5 s bei linearen Wärmeanwendungen (Herstellerangabe mit Bezug auf EN 54-22)\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eFaserbruchalarm\u003c\/th\u003e\n\u003ctd\u003eAutomatische Erkennung, Ortungsgenauigkeit \u0026lt; ±5 m\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eMessbarer Temperaturbereich\u003c\/th\u003e\n\u003ctd\u003e-220 bis +800 °C, abhängig vom eingesetzten faseroptischen Sensorkabel\u003c\/td\u003e\n\u003c\/tr\u003e      \u003c\/tbody\u003e    \u003c\/table\u003e  \u003c\/div\u003e  \u003ch3\u003eOptische, elektrische und mechanische Daten\u003c\/h3\u003e  \u003cdiv\u003e    \u003ctable\u003e      \u003ctbody\u003e        \u003ctr\u003e\n\u003cth\u003eLaserwellenlänge\u003c\/th\u003e\n\u003ctd\u003e1.550 nm\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eOptisches Budget\u003c\/th\u003e\n\u003ctd\u003e10 dB\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eAnschluss \/ Fasertyp\u003c\/th\u003e\n\u003ctd\u003eE2000 \/ Multimode 62,5\/125\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eLasersicherheitsklasse\u003c\/th\u003e\n\u003ctd\u003eKlasse 1\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eVersorgung \/ Leistungsaufnahme\u003c\/th\u003e\n\u003ctd\u003e24 V DC \/ maximal 85 W\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eBauform \/ Schutzart\u003c\/th\u003e\n\u003ctd\u003e3 HE \/ IP40\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eAbmessungen (B × H × T)\u003c\/th\u003e\n\u003ctd\u003e485 × 133 × 509 mm\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eNettogewicht\u003c\/th\u003e\n\u003ctd\u003e10 kg\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eGehäuse\u003c\/th\u003e\n\u003ctd\u003eLackierter verzinkter Stahl, mattschwarz\u003c\/td\u003e\n\u003c\/tr\u003e      \u003c\/tbody\u003e    \u003c\/table\u003e  \u003c\/div\u003e  \u003ch3\u003eSchnittstellen, Alarmierung und Software\u003c\/h3\u003e  \u003cul\u003e    \u003cli\u003e48 NO\/NC-Relaiskontakte\u003c\/li\u003e    \u003cli\u003eModbus TCP und Modbus RTU\u003c\/li\u003e    \u003cli\u003e1 × RJ45 mit 100 Mbit\/s\u003c\/li\u003e    \u003cli\u003e1 × RS-485, 1 × RS-232 und 1 × USB\u003c\/li\u003e    \u003cli\u003e7-Zoll-Touchscreen mit 1.024 × 600 Pixeln\u003c\/li\u003e    \u003cli\u003eInterner Speicher für mehr als 500.000 Messungen bei 10 km (Hersteller-Benchmark)\u003c\/li\u003e    \u003cli\u003eFOTAS Web mit bis zu 1.000 Zonen und Alarmen für Maximum, Minimum, Anstiegsrate und Abweichung\u003c\/li\u003e  \u003c\/ul\u003e  \u003ch3\u003eUmgebungsbedingungen\u003c\/h3\u003e  \u003cdiv\u003e    \u003ctable\u003e      \u003ctbody\u003e        \u003ctr\u003e\n\u003cth\u003eBetriebstemperatur\u003c\/th\u003e\n\u003ctd\u003e-10 bis +55 °C\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eBetriebsfeuchte\u003c\/th\u003e\n\u003ctd\u003e0 bis 95 % r. F.\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eLagertemperatur\u003c\/th\u003e\n\u003ctd\u003e-10 bis +85 °C\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eLagerfeuchte\u003c\/th\u003e\n\u003ctd\u003e0 bis 95 % r. F., nicht kondensierend\u003c\/td\u003e\n\u003c\/tr\u003e      \u003c\/tbody\u003e    \u003c\/table\u003e  \u003c\/div\u003e  \u003cdiv\u003e    \u003ch3\u003eDTS-System für Ihr Projekt auslegen\u003c\/h3\u003e    \u003cp\u003eFür eine belastbare Systemauswahl müssen Reichweite, Anzahl und Führung der Messkanäle, Sensorkabel, Temperaturbereich, Alarmzonen sowie die Einbindung in Brandmelde-, Leit- oder Automatisierungssysteme gemeinsam betrachtet werden.\u003c\/p\u003e    \u003cp\u003e\u003ca href=\"https:\/\/shop.abatec.de\/pages\/kontakt\"\u003eSprechen Sie mit abatec über Ihre DTS-Anwendung und die technische Projektierung.\u003c\/a\u003e\u003c\/p\u003e  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"FOTAS","offers":[{"title":"Default Title","offer_id":67581903176070,"sku":"DTS-CH4-02KM","price":25100.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1111\/8768\/9862\/files\/image_1950_2af4089d-e1e5-4fdb-9caf-b96b6674933d.webp?v=1791369909"},{"product_id":"fotas-dts-ch4-4km-temperatursensor","title":"FOTAS DTS 4 km CH4 Vierkanal-Temperatursensorsystem | DTS-CH4-04KM","description":"\u003cdiv data-product-description=\"fotas-dts-ch4-4km\"\u003e  \u003ch2\u003e\u003cfont color=\"#000000\"\u003eFOTAS DTS 4 km CH4 - verteilte Temperaturmessung für Brandfrüherkennung und Anlagenüberwachung\u003c\/font\u003e\u003c\/h2\u003e  \u003cp\u003eDas \u003cstrong\u003eFOTAS DTS 4 km CH4\u003c\/strong\u003e ist ein faseroptisches System für Distributed Temperature Sensing (DTS). Es erfasst Temperaturverläufe entlang eines Sensorkabels räumlich aufgelöst und eignet sich damit für die kontinuierliche thermische Überwachung ausgedehnter Anlagen und Infrastrukturen.\u003c\/p\u003e  \u003cp\u003eDie angebotene CH4-Ausführung ist für eine Konfiguration mit vier Messkanälen vorgesehen. Das offizielle FOTAS-Datenblatt führt für die 4-km-Variante Reichweiten von bis zu 4 km je Kanal sowie Gerätevarianten mit einem, zwei oder vier Kanälen auf. Dadurch lassen sich mehrere Überwachungsbereiche von einer zentralen Einheit aus erfassen.\u003c\/p\u003e  \u003ch3\u003eSo funktioniert Distributed Temperature Sensing\u003c\/h3\u003e  \u003cp\u003eDas DTS-Gerät sendet Laserlicht mit 1.550 nm in eine multimodale Glasfaser. Aus dem temperaturabhängigen rückgestreuten Licht ermittelt das System fortlaufend Temperaturwerte entlang der gesamten Messstrecke. Auf diese Weise wird das Sensorkabel zu einem linienförmigen Temperatursensor mit einem Abtastintervall von 1 m.\u003c\/p\u003e  \u003cp\u003eFür die 4-km-Ausführung nennt der Hersteller eine Temperaturauflösung von 0,1 °C bei 10 Sekunden Messzeit und eine Temperaturgenauigkeit von ±1 °C. Ein Faserbruch wird automatisch erkannt und mit einer Genauigkeit von weniger als ±5 m lokalisiert.\u003c\/p\u003e  \u003cfont color=\"#222222\"\u003e\u003cspan\u003e\u003cimg src=\"https:\/\/eu.myikas.com\/images\/2dc48198-b7a0-4f63-8807-7824d0c41208\/1ff1a47e-3319-4367-8112-eec1bf883663\/720\/1.webp\" alt=\"FOTAS DTS CH4 Vierkanal-System für verteilte Temperaturmessung bis 4 km je Kanal\" title=\"FOTAS DTS-CH4-04KM Distributed Temperature Sensing\" loading=\"lazy\"\u003e\u003c\/span\u003e\u003c\/font\u003e  \u003ch3\u003eIhre Vorteile auf einen Blick\u003c\/h3\u003e  \u003cul\u003e    \u003cli\u003e\n\u003cstrong\u003eVerteilte Messung:\u003c\/strong\u003e Temperaturdaten entlang der gesamten Glasfaser statt nur an einzelnen Messpunkten\u003c\/li\u003e    \u003cli\u003e\n\u003cstrong\u003eGroße Reichweite:\u003c\/strong\u003e bis zu 4 km je Kanal\u003c\/li\u003e    \u003cli\u003e\n\u003cstrong\u003eVierkanal-Konfiguration:\u003c\/strong\u003e mehrere Messstrecken oder Anlagenbereiche zentral überwachen\u003c\/li\u003e    \u003cli\u003e\n\u003cstrong\u003eGenaue Lokalisierung:\u003c\/strong\u003e 1 m Abtastintervall und automatische Faserbruchmeldung\u003c\/li\u003e    \u003cli\u003e\n\u003cstrong\u003eSystemintegration:\u003c\/strong\u003e Modbus TCP, Modbus RTU, Relais, Ethernet und serielle Schnittstellen\u003c\/li\u003e    \u003cli\u003e\n\u003cstrong\u003eFlexible Alarmierung:\u003c\/strong\u003e Grenzwert-, Minimum-, Temperaturanstiegs- und Abweichungsalarme\u003c\/li\u003e  \u003c\/ul\u003e  \u003ch3\u003eTypische Einsatzbereiche\u003c\/h3\u003e  \u003cul\u003e    \u003cli\u003eLineare Brandfrüherkennung in Straßen-, Bahn- und Versorgungstunneln\u003c\/li\u003e    \u003cli\u003eThermische Überwachung von Energie- und Leistungskabeln\u003c\/li\u003e    \u003cli\u003eTemperaturüberwachung in Industrieanlagen, Lagern und Rechenzentren\u003c\/li\u003e    \u003cli\u003eErkennung thermischer Auffälligkeiten entlang von Rohrleitungen und technischen Trassen\u003c\/li\u003e    \u003cli\u003eZonenbasierte Überwachung komplexer Infrastrukturprojekte\u003c\/li\u003e  \u003c\/ul\u003e  \u003ch3\u003eTechnische Highlights\u003c\/h3\u003e  \u003cdiv\u003e    \u003ctable\u003e      \u003ctbody\u003e        \u003ctr\u003e\n\u003cth\u003eArtikelnummer \/ Ausführung\u003c\/th\u003e\n\u003ctd\u003eDTS-CH4-04KM \/ CH4\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eSensortechnologie\u003c\/th\u003e\n\u003ctd\u003eDistributed Temperature Sensing (DTS)\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eReichweite\u003c\/th\u003e\n\u003ctd\u003eBis zu 4 km je Kanal\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eKanaloptionen laut Hersteller\u003c\/th\u003e\n\u003ctd\u003e1 \/ 2 \/ 4; Shopausführung CH4\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eAbtastintervall\u003c\/th\u003e\n\u003ctd\u003e1 m\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eTemperaturauflösung bei 4 km\u003c\/th\u003e\n\u003ctd\u003e0,1 °C bei 10 s\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eTemperaturgenauigkeit\u003c\/th\u003e\n\u003ctd\u003e±1 °C\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eMesszeit\u003c\/th\u003e\n\u003ctd\u003eTypisch ca. 5 s bei linearen Wärmeanwendungen (Herstellerangabe mit Bezug auf EN 54-22)\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eFaserbruchalarm\u003c\/th\u003e\n\u003ctd\u003eAutomatische Erkennung, Ortungsgenauigkeit \u0026lt; ±5 m\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eMessbarer Temperaturbereich\u003c\/th\u003e\n\u003ctd\u003e-220 bis +800 °C, abhängig vom eingesetzten faseroptischen Sensorkabel\u003c\/td\u003e\n\u003c\/tr\u003e      \u003c\/tbody\u003e    \u003c\/table\u003e  \u003c\/div\u003e  \u003ch3\u003eOptische, elektrische und mechanische Daten\u003c\/h3\u003e  \u003cdiv\u003e    \u003ctable\u003e      \u003ctbody\u003e        \u003ctr\u003e\n\u003cth\u003eLaserwellenlänge\u003c\/th\u003e\n\u003ctd\u003e1.550 nm\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eOptisches Budget\u003c\/th\u003e\n\u003ctd\u003e10 dB\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eAnschluss \/ Fasertyp\u003c\/th\u003e\n\u003ctd\u003eE2000 \/ Multimode 62,5\/125\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eLasersicherheitsklasse\u003c\/th\u003e\n\u003ctd\u003eKlasse 1\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eVersorgung \/ Leistungsaufnahme\u003c\/th\u003e\n\u003ctd\u003e24 V DC \/ maximal 85 W\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eBauform \/ Schutzart\u003c\/th\u003e\n\u003ctd\u003e3 HE \/ IP40\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eAbmessungen (B × H × T)\u003c\/th\u003e\n\u003ctd\u003e485 × 133 × 509 mm\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eNettogewicht\u003c\/th\u003e\n\u003ctd\u003e10 kg\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eGehäuse\u003c\/th\u003e\n\u003ctd\u003eLackierter verzinkter Stahl, mattschwarz\u003c\/td\u003e\n\u003c\/tr\u003e      \u003c\/tbody\u003e    \u003c\/table\u003e  \u003c\/div\u003e  \u003ch3\u003eSchnittstellen, Alarmierung und Software\u003c\/h3\u003e  \u003cul\u003e    \u003cli\u003e48 NO\/NC-Relaiskontakte\u003c\/li\u003e    \u003cli\u003eModbus TCP und Modbus RTU\u003c\/li\u003e    \u003cli\u003e1 × RJ45 mit 100 Mbit\/s\u003c\/li\u003e    \u003cli\u003e1 × RS-485, 1 × RS-232 und 1 × USB\u003c\/li\u003e    \u003cli\u003e7-Zoll-Touchscreen mit 1.024 × 600 Pixeln\u003c\/li\u003e    \u003cli\u003eInterner Speicher für mehr als 500.000 Messungen bei 10 km (Hersteller-Benchmark)\u003c\/li\u003e    \u003cli\u003eFOTAS Web mit bis zu 1.000 Zonen und Alarmen für Maximum, Minimum, Anstiegsrate und Abweichung\u003c\/li\u003e  \u003c\/ul\u003e  \u003ch3\u003eUmgebungsbedingungen\u003c\/h3\u003e  \u003cdiv\u003e    \u003ctable\u003e      \u003ctbody\u003e        \u003ctr\u003e\n\u003cth\u003eBetriebstemperatur\u003c\/th\u003e\n\u003ctd\u003e-10 bis +55 °C\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eBetriebsfeuchte\u003c\/th\u003e\n\u003ctd\u003e0 bis 95 % r. F.\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eLagertemperatur\u003c\/th\u003e\n\u003ctd\u003e-10 bis +85 °C\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eLagerfeuchte\u003c\/th\u003e\n\u003ctd\u003e0 bis 95 % r. F., nicht kondensierend\u003c\/td\u003e\n\u003c\/tr\u003e      \u003c\/tbody\u003e    \u003c\/table\u003e  \u003c\/div\u003e  \u003cdiv\u003e    \u003ch3\u003eDTS-System für Ihr Projekt auslegen\u003c\/h3\u003e    \u003cp\u003eFür eine belastbare Systemauswahl müssen Reichweite, Anzahl und Führung der Messkanäle, Sensorkabel, Temperaturbereich, Alarmzonen sowie die Einbindung in Brandmelde-, Leit- oder Automatisierungssysteme gemeinsam betrachtet werden.\u003c\/p\u003e    \u003cp\u003e\u003ca href=\"https:\/\/shop.abatec.de\/pages\/kontakt\"\u003eSprechen Sie mit abatec über Ihre DTS-Anwendung und die technische Projektierung.\u003c\/a\u003e\u003c\/p\u003e  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"FOTAS","offers":[{"title":"Default Title","offer_id":67581903241606,"sku":"DTS-CH4-04KM","price":26910.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1111\/8768\/9862\/files\/image_1950_3d5a0bc4-ad63-4e66-b966-751b2c97cf56.webp?v=1791369910"},{"product_id":"fotas-dts-ch4-8km-temperatursensor","title":"FOTAS DTS 8 km 4CH Vierkanal-Temperatursensorsystem | DTS-CH4-08KM","description":"\u003cdiv data-product-description=\"fotas-dts-ch4-8km\"\u003e  \u003ch2\u003e\u003cfont color=\"#000000\"\u003eFOTAS DTS 8 km 4CH - verteilte Temperaturmessung für Brandfrüherkennung und Anlagenüberwachung\u003c\/font\u003e\u003c\/h2\u003e  \u003cp\u003eDas \u003cstrong\u003eFOTAS DTS 8 km 4CH\u003c\/strong\u003e ist ein faseroptisches System für Distributed Temperature Sensing (DTS). Es erfasst Temperaturverläufe entlang eines Sensorkabels räumlich aufgelöst und eignet sich damit für die kontinuierliche thermische Überwachung ausgedehnter Anlagen und Infrastrukturen.\u003c\/p\u003e  \u003cp\u003eDie angebotene CH4-Ausführung ist für eine Konfiguration mit vier Messkanälen vorgesehen. Das offizielle FOTAS-Datenblatt führt für die 8-km-Variante Reichweiten von bis zu 8 km je Kanal sowie Gerätevarianten mit einem, zwei oder vier Kanälen auf. Dadurch lassen sich mehrere Überwachungsbereiche von einer zentralen Einheit aus erfassen.\u003c\/p\u003e  \u003ch3\u003eSo funktioniert Distributed Temperature Sensing\u003c\/h3\u003e  \u003cp\u003eDas DTS-Gerät sendet Laserlicht mit 1.550 nm in eine multimodale Glasfaser. Aus dem temperaturabhängigen rückgestreuten Licht ermittelt das System fortlaufend Temperaturwerte entlang der gesamten Messstrecke. Auf diese Weise wird das Sensorkabel zu einem linienförmigen Temperatursensor mit einem Abtastintervall von 1 m.\u003c\/p\u003e  \u003cp\u003eFür die 8-km-Ausführung nennt der Hersteller eine Temperaturauflösung von 0,3 °C bei 10 Sekunden Messzeit und eine Temperaturgenauigkeit von ±1 °C. Ein Faserbruch wird automatisch erkannt und mit einer Genauigkeit von weniger als ±5 m lokalisiert.\u003c\/p\u003e  \u003cfont color=\"#222222\"\u003e\u003cspan\u003e\u003cimg src=\"https:\/\/eu.myikas.com\/images\/2dc48198-b7a0-4f63-8807-7824d0c41208\/81ee9006-03b5-4c7a-822b-331b506a188a\/720\/1.webp\" alt=\"FOTAS DTS CH4 Vierkanal-System für verteilte Temperaturmessung bis 8 km je Kanal\" title=\"FOTAS DTS-CH4-08KM Distributed Temperature Sensing\" loading=\"lazy\"\u003e\u003c\/span\u003e\u003c\/font\u003e  \u003ch3\u003eIhre Vorteile auf einen Blick\u003c\/h3\u003e  \u003cul\u003e    \u003cli\u003e\n\u003cstrong\u003eVerteilte Messung:\u003c\/strong\u003e Temperaturdaten entlang der gesamten Glasfaser statt nur an einzelnen Messpunkten\u003c\/li\u003e    \u003cli\u003e\n\u003cstrong\u003eGroße Reichweite:\u003c\/strong\u003e bis zu 8 km je Kanal\u003c\/li\u003e    \u003cli\u003e\n\u003cstrong\u003eVierkanal-Konfiguration:\u003c\/strong\u003e mehrere Messstrecken oder Anlagenbereiche zentral überwachen\u003c\/li\u003e    \u003cli\u003e\n\u003cstrong\u003eGenaue Lokalisierung:\u003c\/strong\u003e 1 m Abtastintervall und automatische Faserbruchmeldung\u003c\/li\u003e    \u003cli\u003e\n\u003cstrong\u003eSystemintegration:\u003c\/strong\u003e Modbus TCP, Modbus RTU, Relais, Ethernet und serielle Schnittstellen\u003c\/li\u003e    \u003cli\u003e\n\u003cstrong\u003eFlexible Alarmierung:\u003c\/strong\u003e Grenzwert-, Minimum-, Temperaturanstiegs- und Abweichungsalarme\u003c\/li\u003e  \u003c\/ul\u003e  \u003ch3\u003eTypische Einsatzbereiche\u003c\/h3\u003e  \u003cul\u003e    \u003cli\u003eLineare Brandfrüherkennung in Straßen-, Bahn- und Versorgungstunneln\u003c\/li\u003e    \u003cli\u003eThermische Überwachung von Energie- und Leistungskabeln\u003c\/li\u003e    \u003cli\u003eTemperaturüberwachung in Industrieanlagen, Lagern und Rechenzentren\u003c\/li\u003e    \u003cli\u003eErkennung thermischer Auffälligkeiten entlang von Rohrleitungen und technischen Trassen\u003c\/li\u003e    \u003cli\u003eZonenbasierte Überwachung komplexer Infrastrukturprojekte\u003c\/li\u003e  \u003c\/ul\u003e  \u003ch3\u003eTechnische Highlights\u003c\/h3\u003e  \u003cdiv\u003e    \u003ctable\u003e      \u003ctbody\u003e        \u003ctr\u003e\n\u003cth\u003eArtikelnummer \/ Ausführung\u003c\/th\u003e\n\u003ctd\u003eDTS-CH4-08KM \/ CH4\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eSensortechnologie\u003c\/th\u003e\n\u003ctd\u003eDistributed Temperature Sensing (DTS)\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eReichweite\u003c\/th\u003e\n\u003ctd\u003eBis zu 8 km je Kanal\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eKanaloptionen laut Hersteller\u003c\/th\u003e\n\u003ctd\u003e1 \/ 2 \/ 4; Shopausführung CH4\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eAbtastintervall\u003c\/th\u003e\n\u003ctd\u003e1 m\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eTemperaturauflösung bei 8 km\u003c\/th\u003e\n\u003ctd\u003e0,3 °C bei 10 s\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eTemperaturgenauigkeit\u003c\/th\u003e\n\u003ctd\u003e±1 °C\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eMesszeit\u003c\/th\u003e\n\u003ctd\u003eTypisch ca. 5 s bei linearen Wärmeanwendungen (Herstellerangabe mit Bezug auf EN 54-22)\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eFaserbruchalarm\u003c\/th\u003e\n\u003ctd\u003eAutomatische Erkennung, Ortungsgenauigkeit \u0026lt; ±5 m\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eMessbarer Temperaturbereich\u003c\/th\u003e\n\u003ctd\u003e-220 bis +800 °C, abhängig vom eingesetzten faseroptischen Sensorkabel\u003c\/td\u003e\n\u003c\/tr\u003e      \u003c\/tbody\u003e    \u003c\/table\u003e  \u003c\/div\u003e  \u003ch3\u003eOptische, elektrische und mechanische Daten\u003c\/h3\u003e  \u003cdiv\u003e    \u003ctable\u003e      \u003ctbody\u003e        \u003ctr\u003e\n\u003cth\u003eLaserwellenlänge\u003c\/th\u003e\n\u003ctd\u003e1.550 nm\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eOptisches Budget\u003c\/th\u003e\n\u003ctd\u003e10 dB\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eAnschluss \/ Fasertyp\u003c\/th\u003e\n\u003ctd\u003eE2000 \/ Multimode 62,5\/125\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eLasersicherheitsklasse\u003c\/th\u003e\n\u003ctd\u003eKlasse 1\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eVersorgung \/ Leistungsaufnahme\u003c\/th\u003e\n\u003ctd\u003e24 V DC \/ maximal 85 W\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eBauform \/ Schutzart\u003c\/th\u003e\n\u003ctd\u003e3 HE \/ IP40\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eAbmessungen (B × H × T)\u003c\/th\u003e\n\u003ctd\u003e485 × 133 × 509 mm\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eNettogewicht\u003c\/th\u003e\n\u003ctd\u003e10 kg\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eGehäuse\u003c\/th\u003e\n\u003ctd\u003eLackierter verzinkter Stahl, mattschwarz\u003c\/td\u003e\n\u003c\/tr\u003e      \u003c\/tbody\u003e    \u003c\/table\u003e  \u003c\/div\u003e  \u003ch3\u003eSchnittstellen, Alarmierung und Software\u003c\/h3\u003e  \u003cul\u003e    \u003cli\u003e48 NO\/NC-Relaiskontakte\u003c\/li\u003e    \u003cli\u003eModbus TCP und Modbus RTU\u003c\/li\u003e    \u003cli\u003e1 × RJ45 mit 100 Mbit\/s\u003c\/li\u003e    \u003cli\u003e1 × RS-485, 1 × RS-232 und 1 × USB\u003c\/li\u003e    \u003cli\u003e7-Zoll-Touchscreen mit 1.024 × 600 Pixeln\u003c\/li\u003e    \u003cli\u003eInterner Speicher für mehr als 500.000 Messungen bei 10 km (Hersteller-Benchmark)\u003c\/li\u003e    \u003cli\u003eFOTAS Web mit bis zu 1.000 Zonen und Alarmen für Maximum, Minimum, Anstiegsrate und Abweichung\u003c\/li\u003e  \u003c\/ul\u003e  \u003ch3\u003eUmgebungsbedingungen\u003c\/h3\u003e  \u003cdiv\u003e    \u003ctable\u003e      \u003ctbody\u003e        \u003ctr\u003e\n\u003cth\u003eBetriebstemperatur\u003c\/th\u003e\n\u003ctd\u003e-10 bis +55 °C\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eBetriebsfeuchte\u003c\/th\u003e\n\u003ctd\u003e0 bis 95 % r. F.\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eLagertemperatur\u003c\/th\u003e\n\u003ctd\u003e-10 bis +85 °C\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eLagerfeuchte\u003c\/th\u003e\n\u003ctd\u003e0 bis 95 % r. F., nicht kondensierend\u003c\/td\u003e\n\u003c\/tr\u003e      \u003c\/tbody\u003e    \u003c\/table\u003e  \u003c\/div\u003e  \u003cdiv\u003e    \u003ch3\u003eDTS-System für Ihr Projekt auslegen\u003c\/h3\u003e    \u003cp\u003eFür eine belastbare Systemauswahl müssen Reichweite, Anzahl und Führung der Messkanäle, Sensorkabel, Temperaturbereich, Alarmzonen sowie die Einbindung in Brandmelde-, Leit- oder Automatisierungssysteme gemeinsam betrachtet werden.\u003c\/p\u003e    \u003cp\u003e\u003ca href=\"https:\/\/shop.abatec.de\/pages\/kontakt\"\u003eSprechen Sie mit abatec über Ihre DTS-Anwendung und die technische Projektierung.\u003c\/a\u003e\u003c\/p\u003e  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"FOTAS","offers":[{"title":"Default Title","offer_id":67581903307142,"sku":"DTS-CH4-08KM","price":29240.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1111\/8768\/9862\/files\/image_1950_5a82f893-c27b-44e6-986b-2e311d6c234a.webp?v=1791369910"},{"product_id":"fotas-dts-ch4-10km-temperatursensor","title":"FOTAS DTS 10 km CH4 Vierkanal-Temperatursensorsystem | DTS-CH4-10KM","description":"\u003cdiv data-product-description=\"fotas-dts-ch4-10km\"\u003e  \u003ch2\u003e\u003cfont color=\"#000000\"\u003eFOTAS DTS 10 km CH4 - verteilte Temperaturmessung für Brandfrüherkennung und Anlagenüberwachung\u003c\/font\u003e\u003c\/h2\u003e  \u003cp\u003eDas \u003cstrong\u003eFOTAS DTS 10 km CH4\u003c\/strong\u003e ist ein faseroptisches System für Distributed Temperature Sensing (DTS). Es erfasst Temperaturverläufe entlang eines Sensorkabels räumlich aufgelöst und eignet sich damit für die kontinuierliche thermische Überwachung ausgedehnter Anlagen und Infrastrukturen.\u003c\/p\u003e  \u003cp\u003eDie angebotene CH4-Ausführung ist für eine Konfiguration mit vier Messkanälen vorgesehen. Das offizielle FOTAS-Datenblatt führt für die 10-km-Variante Reichweiten von bis zu 10 km je Kanal sowie Gerätevarianten mit einem, zwei oder vier Kanälen auf. Dadurch lassen sich mehrere Überwachungsbereiche von einer zentralen Einheit aus erfassen.\u003c\/p\u003e  \u003ch3\u003eSo funktioniert Distributed Temperature Sensing\u003c\/h3\u003e  \u003cp\u003eDas DTS-Gerät sendet Laserlicht mit 1.550 nm in eine multimodale Glasfaser. Aus dem temperaturabhängigen rückgestreuten Licht ermittelt das System fortlaufend Temperaturwerte entlang der gesamten Messstrecke. Auf diese Weise wird das Sensorkabel zu einem linienförmigen Temperatursensor mit einem Abtastintervall von 1 m.\u003c\/p\u003e  \u003cp\u003eFür die 10-km-Ausführung nennt der Hersteller eine Temperaturauflösung von 0,3 °C bei 10 Sekunden Messzeit und eine Temperaturgenauigkeit von ±1 °C. Ein Faserbruch wird automatisch erkannt und mit einer Genauigkeit von weniger als ±5 m lokalisiert.\u003c\/p\u003e  \u003cfont color=\"#222222\"\u003e\u003cspan\u003e\u003cimg src=\"https:\/\/eu.myikas.com\/images\/2dc48198-b7a0-4f63-8807-7824d0c41208\/d817f466-b2ef-4672-bc5e-3137a706c1d6\/720\/1.webp\" alt=\"FOTAS DTS CH4 Vierkanal-System für verteilte Temperaturmessung bis 10 km je Kanal\" title=\"FOTAS DTS-CH4-10KM Distributed Temperature Sensing\" loading=\"lazy\"\u003e\u003c\/span\u003e\u003c\/font\u003e  \u003ch3\u003eIhre Vorteile auf einen Blick\u003c\/h3\u003e  \u003cul\u003e    \u003cli\u003e\n\u003cstrong\u003eVerteilte Messung:\u003c\/strong\u003e Temperaturdaten entlang der gesamten Glasfaser statt nur an einzelnen Messpunkten\u003c\/li\u003e    \u003cli\u003e\n\u003cstrong\u003eGroße Reichweite:\u003c\/strong\u003e bis zu 10 km je Kanal\u003c\/li\u003e    \u003cli\u003e\n\u003cstrong\u003eVierkanal-Konfiguration:\u003c\/strong\u003e mehrere Messstrecken oder Anlagenbereiche zentral überwachen\u003c\/li\u003e    \u003cli\u003e\n\u003cstrong\u003eGenaue Lokalisierung:\u003c\/strong\u003e 1 m Abtastintervall und automatische Faserbruchmeldung\u003c\/li\u003e    \u003cli\u003e\n\u003cstrong\u003eSystemintegration:\u003c\/strong\u003e Modbus TCP, Modbus RTU, Relais, Ethernet und serielle Schnittstellen\u003c\/li\u003e    \u003cli\u003e\n\u003cstrong\u003eFlexible Alarmierung:\u003c\/strong\u003e Grenzwert-, Minimum-, Temperaturanstiegs- und Abweichungsalarme\u003c\/li\u003e  \u003c\/ul\u003e  \u003ch3\u003eTypische Einsatzbereiche\u003c\/h3\u003e  \u003cul\u003e    \u003cli\u003eLineare Brandfrüherkennung in Straßen-, Bahn- und Versorgungstunneln\u003c\/li\u003e    \u003cli\u003eThermische Überwachung von Energie- und Leistungskabeln\u003c\/li\u003e    \u003cli\u003eTemperaturüberwachung in Industrieanlagen, Lagern und Rechenzentren\u003c\/li\u003e    \u003cli\u003eErkennung thermischer Auffälligkeiten entlang von Rohrleitungen und technischen Trassen\u003c\/li\u003e    \u003cli\u003eZonenbasierte Überwachung komplexer Infrastrukturprojekte\u003c\/li\u003e  \u003c\/ul\u003e  \u003ch3\u003eTechnische Highlights\u003c\/h3\u003e  \u003cdiv\u003e    \u003ctable\u003e      \u003ctbody\u003e        \u003ctr\u003e\n\u003cth\u003eArtikelnummer \/ Ausführung\u003c\/th\u003e\n\u003ctd\u003eDTS-CH4-10KM \/ CH4\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eSensortechnologie\u003c\/th\u003e\n\u003ctd\u003eDistributed Temperature Sensing (DTS)\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eReichweite\u003c\/th\u003e\n\u003ctd\u003eBis zu 10 km je Kanal\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eKanaloptionen laut Hersteller\u003c\/th\u003e\n\u003ctd\u003e1 \/ 2 \/ 4; Shopausführung CH4\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eAbtastintervall\u003c\/th\u003e\n\u003ctd\u003e1 m\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eTemperaturauflösung bei 10 km\u003c\/th\u003e\n\u003ctd\u003e0,3 °C bei 10 s\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eTemperaturgenauigkeit\u003c\/th\u003e\n\u003ctd\u003e±1 °C\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eMesszeit\u003c\/th\u003e\n\u003ctd\u003eTypisch ca. 5 s bei linearen Wärmeanwendungen (Herstellerangabe mit Bezug auf EN 54-22)\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eFaserbruchalarm\u003c\/th\u003e\n\u003ctd\u003eAutomatische Erkennung, Ortungsgenauigkeit \u0026lt; ±5 m\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eMessbarer Temperaturbereich\u003c\/th\u003e\n\u003ctd\u003e-220 bis +800 °C, abhängig vom eingesetzten faseroptischen Sensorkabel\u003c\/td\u003e\n\u003c\/tr\u003e      \u003c\/tbody\u003e    \u003c\/table\u003e  \u003c\/div\u003e  \u003ch3\u003eOptische, elektrische und mechanische Daten\u003c\/h3\u003e  \u003cdiv\u003e    \u003ctable\u003e      \u003ctbody\u003e        \u003ctr\u003e\n\u003cth\u003eLaserwellenlänge\u003c\/th\u003e\n\u003ctd\u003e1.550 nm\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eOptisches Budget\u003c\/th\u003e\n\u003ctd\u003e10 dB\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eAnschluss \/ Fasertyp\u003c\/th\u003e\n\u003ctd\u003eE2000 \/ Multimode 62,5\/125\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eLasersicherheitsklasse\u003c\/th\u003e\n\u003ctd\u003eKlasse 1\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eVersorgung \/ Leistungsaufnahme\u003c\/th\u003e\n\u003ctd\u003e24 V DC \/ maximal 85 W\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eBauform \/ Schutzart\u003c\/th\u003e\n\u003ctd\u003e3 HE \/ IP40\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eAbmessungen (B × H × T)\u003c\/th\u003e\n\u003ctd\u003e485 × 133 × 509 mm\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eNettogewicht\u003c\/th\u003e\n\u003ctd\u003e10 kg\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eGehäuse\u003c\/th\u003e\n\u003ctd\u003eLackierter verzinkter Stahl, mattschwarz\u003c\/td\u003e\n\u003c\/tr\u003e      \u003c\/tbody\u003e    \u003c\/table\u003e  \u003c\/div\u003e  \u003ch3\u003eSchnittstellen, Alarmierung und Software\u003c\/h3\u003e  \u003cul\u003e    \u003cli\u003e48 NO\/NC-Relaiskontakte\u003c\/li\u003e    \u003cli\u003eModbus TCP und Modbus RTU\u003c\/li\u003e    \u003cli\u003e1 × RJ45 mit 100 Mbit\/s\u003c\/li\u003e    \u003cli\u003e1 × RS-485, 1 × RS-232 und 1 × USB\u003c\/li\u003e    \u003cli\u003e7-Zoll-Touchscreen mit 1.024 × 600 Pixeln\u003c\/li\u003e    \u003cli\u003eInterner Speicher für mehr als 500.000 Messungen bei 10 km\u003c\/li\u003e    \u003cli\u003eFOTAS Web mit bis zu 1.000 Zonen und Alarmen für Maximum, Minimum, Anstiegsrate und Abweichung\u003c\/li\u003e  \u003c\/ul\u003e  \u003ch3\u003eUmgebungsbedingungen\u003c\/h3\u003e  \u003cdiv\u003e    \u003ctable\u003e      \u003ctbody\u003e        \u003ctr\u003e\n\u003cth\u003eBetriebstemperatur\u003c\/th\u003e\n\u003ctd\u003e-10 bis +55 °C\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eBetriebsfeuchte\u003c\/th\u003e\n\u003ctd\u003e0 bis 95 % r. F.\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eLagertemperatur\u003c\/th\u003e\n\u003ctd\u003e-10 bis +85 °C\u003c\/td\u003e\n\u003c\/tr\u003e        \u003ctr\u003e\n\u003cth\u003eLagerfeuchte\u003c\/th\u003e\n\u003ctd\u003e0 bis 95 % r. F., nicht kondensierend\u003c\/td\u003e\n\u003c\/tr\u003e      \u003c\/tbody\u003e    \u003c\/table\u003e  \u003c\/div\u003e  \u003cdiv\u003e    \u003ch3\u003eDTS-System für Ihr Projekt auslegen\u003c\/h3\u003e    \u003cp\u003eFür eine belastbare Systemauswahl müssen Reichweite, Anzahl und Führung der Messkanäle, Sensorkabel, Temperaturbereich, Alarmzonen sowie die Einbindung in Brandmelde-, Leit- oder Automatisierungssysteme gemeinsam betrachtet werden.\u003c\/p\u003e    \u003cp\u003e\u003ca href=\"https:\/\/shop.abatec.de\/pages\/kontakt\"\u003eSprechen Sie mit abatec über Ihre DTS-Anwendung und die technische Projektierung.\u003c\/a\u003e\u003c\/p\u003e  \u003c\/div\u003e\n\u003c\/div\u003e","brand":"FOTAS","offers":[{"title":"Default Title","offer_id":67581903405446,"sku":"DTS-CH4-10KM","price":31050.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1111\/8768\/9862\/files\/image_1950_95852721-b1ac-4e8e-b4a7-cac4fff5a1c1.webp?v=1791369911"}],"url":"https:\/\/shop.abatec.de\/collections\/fotas-dts-technology.oembed","provider":"abatec B2B Shop","version":"1.0","type":"link"}